Description
Signet Paddlewheel Flow Integral Systems | 9900
| General |
|
|
| Input Channels |
|
One |
| Input Types |
Digital (S3 L) |
Serial ASCII, TTL level, 9600 bps |
|
Frequency |
Range 0.5 to 1500 Hz |
|
|
Accuracy 0.5% of reading |
| Measurement Types |
|
Flow, pH/ORP, Conductivity/Resistivity, Salinity, Pressure,
Temperature, Level, Dissolved Oxygen, Batch or user-defined (via 8058) |
| Enclosure and Display |
|
|
| Case Material |
|
PBT |
| Window |
|
Shatter-resistant glass |
| Keypad |
|
4 buttons, injection-moulded silicone rubber seal |
| Display |
|
Backlit, 7 and 14-segment |
| Update Rate |
|
1 s |
| LCD Contrast |
|
5 settings |
| Indicators |
|
“Dial-type” digital bar graph. LEDs for open collector, relays and warning indicator |
| Enclosure Size |
|
¼ DIN |
| Mounting |
9900-1P |
|
|
Panel |
¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket included.
Optional rear enclosure with flat cover available for waterproof protection when installed inside a panel. |
|
Wall |
Options include 9900-1P installed in pre-wired NEMA enclosure,
wall mount enclosure or inside of rear enclosure with hinged cover. (USA Only) |
|
Pipe |
Optional Rear Enclosure with hinged cover and 9900-1P for pipe mount installation |
| Mounting |
9900-1 |
|
|
Field (Integral) |
Options include yellow universal or integral kits for installation with sensor |
| Display Ranges |
|
|
| pH |
0.00 to 15.00 pH |
|
| pH Temperature |
-99 °C to 350 °C |
-146 °F to 662 °F |
| ORP |
-1999 to +1999 mV |
|
| Flow Rate |
-9999 to 99999 units per second, minute, hour or day |
|
| Totalizer |
0.00 to 99999999 units |
|
| Conductivity |
0.0000 to 99999 μS, mS, PPM and PPB (TDS), kΩ, MΩ |
|
| Conductivity Temperature |
-100 °C to 250 °C |
-148 °F to 350 °F (application and sensor dependent) |
| Temperature |
-99 °C to 350 °C |
-99 °F to 350 °F |
| Pressure |
-40 to 1000 psi |
|
| Level |
-9999 to 99999 m, cm, ft, in, % |
|
| Volume |
0 to 99999 cm3, m3 , in3, ft3 , gal, L, lb, kg, % |
|
| Salinity |
0 to 99.97 PPT |
|
| Dissolved Oxygen |
PPM 0-50, % SAT 0-200, 0 to 999.9 TORR |
|
| Dissolved Oxygen Temperature |
-99 °C to 350 °C |
-99 °F to 350 °F |
| Environmental |
|
|
| Ambient Operating Temp |
|
|
| Backlit LCD |
-10 °C to 70 °C |
14 °F to 158 °F |
| Storage Temperature |
-15 °C to 70 °C |
5 °F to 158 °F |
| Relative Humidity |
|
0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount |
| Maximum Altitude |
4,000 m (13,123 ft) |
|
| Enclosure Rating |
|
NEMA 4X/IP65 (front face only on panel mount); field mount is 100%
NEMA 4X/IP65 when used with universal or integral installation kits |
| Electrical Requirements |
|
|
| Power to Sensors |
|
|
| Voltage |
+4.9 to 5.5 VDC @ 25 °C, regulated |
|
| Current |
1.5 mA max in loop power mode (up to 2.0 mA with 24 V @ 300 ? max. loop impedance);
20 mA max when using DC power |
|
| Short Circuit |
Protected |
|
| Isolation |
Low voltage (< 48V AC/DC) to loop with DC power connected |
|
|
No isolation when using loop power only |
|
| Terminal Blocks |
Pluggable screw type |
14 AWG max wire gauge |
| Input Power |
|
| DC |
10.8 to 35.2 VDC, regulated |
| 9900 without Relay Module |
200 mA @ 10.8 VDC to 35.2 VDC |
| 9900 with Relay Module |
300 mA @ 10.8 VDC to 35.2 VDC |
| Overvoltage Protection |
48 Volt Transient Protection Device |
| Current limiting for circuit protection |
|
| Reverse-Voltage Protection |
| Loop Power |
|
|
|
| Loop Power Only |
|
|
|
| Max. Loop Impedance |
50 Ω @ 12 V |
325 Ω @ 18 V |
600 Ω @ 24 V |
| With DC Power Input or with 2nd loop, all the time |
|
|
|
| Max. Loop Impedance |
250 Ω @ 12 V |
500 Ω @ 18 V |
750 Ω @ 24 V |
| Relay Specifications |
|
|
|
Dry Contact Relays (2) |
Open Collector (1) |
| Type |
SPDT |
N/A |
| Form |
C |
N/A |
| Maximum Current Rating |
5 A resistive |
50 mA DC |
| Maximum Voltage Rating |
30 VDC or 250 VAC |
30 VDC |
| Hysteresis |
Adjustable (absolute in engineering units) (EUs) |
|
| Latch |
Reset in test screen only |
|
| Delay |
9999.9 seconds (max.) |
|
| Test Mode |
Set On or Of |
|
| Cycle Time |
99999 seconds (max.) |
|
| Maximum Pulse Rate |
300 pulses/minute |
|
| Proportional Pulse |
400 pulses/minute |
|
| Volumetric Pulse Width |
0.1 to 3200 s |
|
| Pulse Width Modulation |
0.1 to 320 s |
| Input Types |
| Digital (S3 L) or AC frequency |
| 4 to 20 mA input via the 8058-1 |
| pH/ORP input via the Digital (S3 L) output from the 2751 pH/ORP Sensor Electronics |
| Raw Conductivity/Resistivity input directly from Signet Conductivity/Resistivity electrodes via Direct Conductivity/ Resistivity Module or via 2850 |
| Input Specifications |
|
|
| Digital (S3 L) |
Serial ACSII, TTL level, 9600 bps |
|
| Frequency Input |
Sensitivity |
80 mV @ 5 Hz, gradually increasing with frequency |
|
Span |
0.5 Hz to 1500 Hz @ TTL level input |
|
Accuracy |
± 0.5% or reading max error @ 25 °C |
|
Resolution |
1 μA |
|
Repeatability |
± 0.2% of reading |
| Power Supply |
Rejection |
±1 μA per volt |
|
Short Circuit |
Protected |
| Update Rate |
|
(1/frequency) + 150 ms |
| (1/frequency) + 150 ms |
Accuracy |
Conductivity +/- 2% of Reading |
|
|
Temperature 0.5 °C |
|
Resolution |
Conductivity 0.1% of Reading |
|
|
| Output Specifications |
|
| Current Output – One (1); Two (2) with 4 to 20 mA Output Module |
|
| Current Loop Output Standard |
ANSI-ISA 50.00.01 Class H |
| Current Output |
4 to 20 mA, isolated, fully adjustable and reversible |
| Span |
3.8 to 21 mA |
| Zero |
4.0 mA factory set; user programmable from 3.8 to 5.0 mA |
| Full Scale |
20.00 mA factory set; user programmable from 19.0 to 21.0 mA |
| Accuracy |
±32 μA max. error @ 25 °C @ 24 VDC |
| Resolution |
6 μA or better |
| Temperature Drift |
±1 μA per °C |
| Power Supply Rejection |
±1 μA per V |
| Isolation |
Low voltage ( |
| Voltage |
12 to 32 VDC ±10% |
| Maximum Impedance (with DC power input) |
250 Ω @ 12 VDC
500 Ω @ 18 VDC
750 Ω @ 24 VDC |
| Maximum Impedance (no DC power input) |
50 Ω @ 12 VDC
325 Ω @ 18 VDC
600 Ω @ 24 VDC |
| Update Rate |
150 mS nominal |
| Short circuit and reverse polarity protected |
|
| Adjustable Span |
Reversible |
| Error Condition |
Selectable error condition 3.6 or 22 mA |
| Actual update rate determined by sensor type |
|
| Test Mode |
Increment to desired current (range 3.8 to 21.00 mA) |
| Standards and Approvals |
| CE, UL, CUL, FCC |
| RoHS Compliant, China RoHS |
| Lloyd’s Register |
| Manufactured under ISO 9001, ISO 14001 and ISO 45001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety |
Refer to Models 515/8510, 2536/8512 and 9900 technical specifications for more details on these products
| MFR # |
Pipe Size(inch) |
Code |
Pin / Body |
| 3-9900-1 w/ 3-8510-P0 |
0.5 – 4.0 |
159001733 |
Titanium/ PP |
| 3-9900-1 w/ 3-8510-H0 |
0.5 – 4.0 |
159001734 |
Hastelloy-C / PP |
| 3-9900-1 w/ 3-8510-S0 |
0.5 – 4.0 |
159001735 |
Natural PVDF / PP |
| 3-9900-1 w/ 3-8510-V0 |
0.5 – 4.0 |
Special via DZS |
Hastelloy-C / Natural PVDF |
| 3-9900-1 w/ 3-8510-T0 |
0.5 – 4.0 |
159001736 |
Natural PVDF ; Natural PVDF |
| 3-9900-1 w/ 3-8510-P1 |
5.0 to 8.0 |
159001737 |
Titanium / PP |
| 3-9900-1 w/ 3-8512-P0 |
0.5 – 4.0 |
159001738 |
Titanium / PP |
| 3-9900-1 w/ 3-8512-H0 |
0.5 – 4.0 |
159001739 |
Hastelloy-C / PP |
| 3-9900-1 w/ 3-8512-S0 |
0.5 – 4.0 |
159001740 |
Natural PVDF / PP |
| 3-9900-1 w/ 3-8512-V0 |
0.5 – 4.0 |
159001741 |
Hastelloy-C / Natural PVDF |
| 3-9900-1 w/ 3-8512-T0 |
0.5 – 4.0 |
159001742 |
Natural PVDF / Natural PVDF |
| 3-9900-1 w/ 3-8512-P1 |
5.0 to 8.0 |
159001743 |
Titanium / PP |
Signet Paddlewheel Flow Integral Systems | 9900
Brand
Georg Fischer
Reviews
There are no reviews yet.