Tag: Chemical Production

Chemical Production

  • ULTRASONIC FLOW METER

    Clamp-On Ultrasonic Flow Meter FLO100

    Call for price

    WESS FLO100 Series is the fixed type ultrasonic transit-time flow meter for long-term flow measurement. The flow meter measures the flow rate of liquid in a closed pipe by using a pair of clamp-on sensors. WESS use its own patented technologies such as advanced signal processing and low-voltage operation to achieve high accuracy and reliable performance. Besides, the product provides versatile output interfaces, analog and digital, which can be easily used by a PLC or a flow controller.

    Ultrasonic Flow Meter Flo100 Features

    • Positive / Negative / Net flow totalizer
    •  Proprietary Low-Voltage Transmission and Self-Adaptation Technologies
    • No pipe Cutting or Process Interruption by Using Clamp-On Technology
    •  Able to Measure Electrically Conductive and Non-Conductive Liquids
  • s-can Conductivity Sensor E-511-2-000 condulyser Profile image

    Conductivy Sensor – Condu::lyser

    Call for price

    Overview of Conductivity Sensor Condu-lyser

    The condu::lyser is a maintenance-free and long-term stable probe for online measurement of conductivity, automatically compensated with temperature. It can be mounted directly in the media or in a flow cell providing high precision by either conductive or inductive measurement. Thanks to the 4 electrode high measurement range it is ideal for all varieties of water. One sensor for all applications. 2 versions available one sensor with plug connector for use in monitoring or bypass stations, sensor with fixed cable for submersion directly into media.

    Conductivity sensor Features:
    • s::can plug & measure
    • measurement principle condu::lyser: 4 electrode contacting measurement
    • multi parameter sensor(temp and EC)
    • ideal for surface water, ground water, drinking water and waste water
    • steam sterilizable, autoclavable and compatible with Cleaning In Place (CIP)
    • condu::lyser monitors conductivity, temperature and salinity
    • long term stable and maintenance free in operation
    • high temperature, pressure and measuring range
    • factory pre-calibrated
    • mounting and measurement directly in the media (InSitu) or in a flow cell
    • operation via s::can terminals & s::can software
    • optional: automatic cleaning with compressed air
  • Insertion Magmeter 2551 side vew

    Magmeter Flow Sensor 2551

    Call for price

    Insertion Magmeter Flow Sensor 2551

    The Georg Fischer 2551 Magmeter is an insertion magnetic flow sensor that features no moving parts, available in corrosion-resistant materials to provide long-term reliability with minimal maintenance costs. Material options include PP with stainless steel, PVDF with stainless steel, PVDF with Hastelloy-C, or PVDF with Titanium. Utilizing the comprehensive line of Georg Fischer installation fittings, sensor alignment and insertion depth is automatic. These versatile, simple-to-install sensors deliver accurate flow measurement over a wide dynamic range in pipe sizes ranging from DN15 to DN900 (½ to 36 inches), satisfying the requirements of many applications.

    Georg Fischer 2551 Magmeters offer many output options of frequency/digital (S3L) or 4 to 20 mA which are available on both the blind and display versions. The frequency or digital (S3L) sensor output can be used with Georg Fischer's extensive line of flow instruments while the 4 to 20 mA output can be used for a direct input to PLCs, chart recorders, etc. Both the 4 to 20 mA output and digital (S3L) sensor interface is available for long distance signal transmission. An additional benefit is the empty pipe detection which features a zero flow output when the sensors are not completely wetted. Also, the frequency output is bi-directional while the 4 to 20 mA output can be set for uni- or bi-directional flow using the display or the 3-0250 USB to Digital (S3L) Configuration / Diagnostic set-up tool which connects to PCs for programming capabilities.

    In addition the display version of the 2551 Magmeter is available with relays and features permanent and re-settable total values which can be seen on the display. Also, the display contains multi-languages with English, Spanish, German, French, Italian and Portuguese menu options.

    Magmeter flow sensor features:

    • Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in
    • Operating range: 0.05 to 10 m/s, 0.15 to 33 ft/s
    • Max Pressure rating: PP 10.3 bar @ 25 °C, 150 psi @ 77 °F
    • Power source: 4 to 20mA: 21.6 to 26.4 VDC, 22.1mA max
    • *Only Georg Fischer installation fittings
  • Flow System Transmitter 9900

    Paddle Wheel Flow Meter with Integral Transmitter 9900

    Call for price

    Signet has combined the 9900 SmartPro® Transmitter with the 515/8510 and 2536/8512 Paddlewheel Flow sensors to create integral systems that are easy to order and simple to install. Integral systems are also available in conductivity, level, temperature, and pressure configurations.

    Each integral system features a 9900 Transmitter which provides a local and easy to read LCD display. The push button keypad makes it easy to navigate through the transmitter’s menu. The DC-powered 9900 features a scalable 4 to 20 mA output and open collector for process control.

    Flow Integral Systems with 9900 Transmitters are combined with Signet’s field-proven Models 515/8510 and 2536/8512. These sensors reliably perform in flow ranges from 0.3 to 6 m/s (1 to 20 ft/s) and 0.1 to 6 m/s (0.3 to 20 ft/s) respectively for pipe sizes from ½ to 8 inches. They are available in a variety of materials including polypropylene and PVDF and are easily mounted in the pipe using Signet’s comprehensive line of standard fittings.

    Paddle wheel Flow meter Features

    • Warning LED indicator
    • Selectable error mode for current outputs, 3.6 mA or 22 mA
    • Large auto-sensing backlit display with “at a glance” visibility
    • Local display for sensor mounted instruments
    • Provides 4 to 20 mA output
    • "Dial-type" digital bar graph
    • NEMA 4X/IP65
  • paddle wheel flow sensor Profile image

    Standard Mount Paddlewheel Flow sensor -515

    Call for price

    Overview of Paddle Wheel flow sensor 515

    The Model 515 sensors are offered in a variety of materials for a wide range of pipe sizes and insertion configurations. The many material choices include PP and PVDF make this model highly versatile and chemically compatible to many liquid process solutions. Sensors can be installed in up to DN900 (36 in.) pipes using Signet's comprehensive line of custom fittings which include tees, saddles, and weldolets, set the sensor to the proper insertion depth into the process flow. The sensors are also offered in configurations for wet-tap and intrinsically safe installation requirements.

    Simple to install with time honored reliable performance, Model 515 Rotor-X paddle wheel flow sensors are highly repeatable, rugged sensors that offer exceptional value with little or no maintenance. The output signal of the Model 515 is a sinusoidal frequency capable of driving a self-powered flowmeter (Model 5090). The wide dynamic flow range of 0.3 to 6 m/s (1 to 20 ft/s) allows the sensor to measure liquid flow rates in full pipes and can be used in low pressure systems.

    Paddle wheel flow sensor features

    • Operating range: 0.3 to 6 m/s, 1 to 20 ft/s
    • Simple, economical design
    • Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in
    • Max Pressure rating: PP 12.5 bar @ 20 °C, 180 psi @ 68 °F PVDF 14 bar @ 20 °C, 200 psi @ 68 °F
    • Power source: Self powered
    • Highly repeatable output
    • Chemically resistant materials
    • Compatibility: 8150, 8900, 9900, 9900-1BC, 9950
    • *Only Signet installation fittings
  • Ultrasonic Level Meter LEV100

    Call for price

    LEV100 Ultrasonic Level Meter Overview

    WESS LEV100 ultrasonic level meter utilizes enhanced ultrasonic technology to measure liquid or solid level in various applications with superior accuracy and reliability. The instrument continuously provides the user with important information which includes numeric & graphic screens representing the distance to medium level, an echo profile image to ensure correct configuration during commissioning and saved data analysis for maximum 400 days. LEV100 series offer two types of controllers and various types of sensors to suit for most field requirements. Its isolated electric design enables fit-and-forget performance.

    Ultrasonic Level Meter LEV100 Features

    • Continuous Measurement
    • Single or Dual Channel Measurement
    • 10,000 Points Data Logging & Trend Mode
    • Various Types of Sensors
    • ASF (Automatic Signal Filter)
    • Agitator Free Algorithm
    • Automatic Temperature Compensation
    • Max 400 days data logging
    • Narrow ultrasonic beam angle (3 degree)
  • DENSITY METER

    Ultrasonic Sludge Density Meter ENV200

    Call for price

    Ultrasonic Sludge Density Meter ENV200 Overview

    The ENV200 is an ultrasonic instrument that measures the density of suspended solid in liquid. It consists of sensors, a controller, and a junction box.

    ENV200 with PCM(Process Condition Monitoring) algorithm measures not only the size of received signal which is often measured by conventional ultrasonic density meters but also observes changes in sound velocity and temperatures in the process. As it monitors operational status and water status in pipe and then decides the validity of each measurement it contributes to increasing stability and reliability of the measurement. The ENV-200 utilizes the EEA (Envelope Energy Average) method that saves reception signal envelop and then calculates its energy, rather than using the reception signal’s amplitude change.

    ENV-200 offers three types of sensors, such as spool-piece, tank-mount, and clamp-on type to accommodate all field demands at installation.

    Sludge Density Meter ENV200 Product Features

    1. Continuous measurement
    2. Process monitoring possible (run, stop, full, empty)
    3. 10,000 points data logging
    4. EEAM(Envelope Energy Average Method)
    5. Various types of sensors