Tag: Surface Water

Surface Water

  • pH Probe | pH::lyser

    Price range: R23,116.00 through R37,396.00

    pH Probes Overview

    The pH::lyser is a low maintenance pH sensor for the real-time measurement of pH and temperature directly in the medium or in aby pass flow-cell. Even under tough conditions (up to 90°C) or in water with very low conductivity long term stability and precise measurement is ensured. The sensor is pre-calibrated ex works and immediately ready.

    pH::lyser eco monitors pH & temperature
    pH::lyser pro: high temperature and pH range

    pH Probe Features

    • ideal for surface water, ground water, drinking water and waste water
    • s::can plug & measure
    • measuring principle: unique, non-porous / non-leaking combined reference electrode for technically unrivalled and consistent pH performance
    • multi-parameter sensor
    • long term stable and maintenance free in operation
    • factory pre-calibrated
    • mounting and measurement directly in the media (InSitu) or in flow cell
    • operation via s::can terminals & s::can software
    • optional: automatic cleaning with compressed air
  • Dissolved Oxygen Sensor | oxi::lyser DO

    R46,646.00

    Dissolved Oxygen Sensor - Overview

    The oxi::lyser is used in direct contact with water and measures dissolved oxygen (DO) and temperature. It needs minimal calibration and very little maintenance. The oxi::lyser™ does not need a minimum flow to produce accurate readings and integrates the temperature measurement for online correction. The sensing element, which uses the principle of fluorescence for oxygen measurement, is neither affected nor damaged by direct exposure to sunlight. It can be cleaned automatically with compressed air to ensure fouling is kept to a minimum. The simple plug connection provides power supply and data communication. The oxi::lyser is then connected to a s::can terminal and is ready for use. The “plug & measure” principle avoids complex installation procedures on-site and not only saves time during initial operation but also reduces avoidable errors. The optimised design eliminates all moving parts in contact with the water. This reduces failures and maintenance dramatically. As it uses standardised mounting devices, installation is quick and effortless, either submersed (InSitu) or in a flow-through setup (by-pass, monitoring station).

    The oxi::lyser is used in online control of the aeration of the biological carbon as well as the removal of nitrogen. Activated sludge increases its activity with rising oxygen concentrations, but this increase is not linear: Above approximately 2.5 mg/L a further elevation in oxygen does not increase the nitrification enough to justify the rise in costs of aeration. Furthermore, too-high oxygen concentrations interfere with the process of denitrification. Therefore oxygen concentration must be controlled online in the entire biological nitrogen removal process. Used in combination with the nitro::lyser™ and the ammo::lyser™ operational procedures can be optimised.

    In drinking water applications Dissolved Oxygen is mainly used in early warning systems detecting problems in raw water quality:  Reduced dissolved oxygen concentrations are often an indicator of harmful microbial or chemical contaminations of the water.

    Applied in natural waters or on fish farms the oxi::lyser™ can detect anaerobic conditions, which are life-threatening aquatic organisms, and thus it helps to prevent ecological as well as economic damage.

    Dissolved Oxygen Sensor - Features

    • s::can plug & measure 
    • easy installation
    • measuring principle: optical / fluorescence
    • multiparameter sensor
    • ideal for surface water, groundwater, drinking water, & wastewater
    • long-term stability 
    • virtually maintenance-free 
    • factory pre-calibrated
    • automatic cleaning with compressed air
    • mounting and measurement directly in the media (InSitu) or in Bypass
    • no flow necessary
    • operation via s::can terminals & s::can software
    • no consumables needed

     

  • Chlorine Analyzer | 4630

    R126,188.00

    Chlorine Analyzer - Overview

    The Chlorine Analyzer is an integrated all-in-one system designed to measure free chlorine. It has a pH sensor that is used to accurately measure free chlorine in applications that have varying pH values (±0.20 pH units).  Because free chlorine concentration is pH-dependent, the Chemical Guard feature interrupts/disables the relay that is assigned to the oxidant chemical (such as sodium hydrochloride) until the pH of the application is corrected. The 4630 series also comes complete with a flow switch that will disable the mechanical relays to the dosing pumps when the system is off or the flow is interrupted to the flow cell. The unique integrated clear flow cell accommodates the free chlorine and pH electrode, flow regulator, filter, and variable area flow indicator in one compact unit. An integrated flow regulator with a removable filter accepts inlet pressures of 1 to 8 bar (15 to 120 psi) while maintaining constant flow and minimal pressure to the sensors. Water flows vertically into the sensor tip eliminating bubble entrapment. The flow cell is designed to maintain a minimum amount of water to ensure sensors stay submerged, even when the system and flow is turned off. The 4630 Free Chlorine Analyzer System comes complete with everything needed to support chlorine monitoring for 1 full year of operation. Panel design allows quick and easy installation and comes complete with four 4 to 20 mA outputs, a flow switch with relay interrupt, four binary inputs, and two mechanical relays.

    Chlorine Analyzer - Features

    • EPA 334.0 Compliant
    • Reagent-free measuring
    • Chemical Guard prevents overdosing on oxidants chemicals
    • Built-in flow switch
    • Chlorine and pH electrode performance data
    • Automatic timestamp after successful calibration
    • Customer-enabled alarm feature for recalibration
    • Complete panel system allows for quick and easy installation
    • Built-in flow regulator maintains constant flow and pressure to the sensors regardless of inlet pressure
    • Automatic pH compensation

    Datasheet

  • Amperometric Chlorine Dioxide Electrode | GF2632

    Amperometric Chlorine Dioxide Electrode - Overview

    This electrode is designed to measure residual chlorine dioxide in water treatment applications. The electrode is available with a measurement range of 0.02 to 2 ppm. This electrode requires the electrode to output a digital (S3L) signal to the 9950-X Chlorine Controller. Utilising smart-sensor technology, this electrode has a unique embedded memory chip and can communicate a wide variety of information to the 9950-X Chlorine Controller. The 9950-X can display the electrode's stored information including the serial number, electrode type, service time in hours, chlorine range, and high and low temperatures. The patented DryLoc® connector with its gold-plated contacts and O-ring seal ensures a waterproof and reliable interconnect to the 2650 electronics. This allows quick assembly during system start-up while providing an easy way to service or replace the Amperometric electrode. This electrode is required to be in chlorinated water at ALL times.

    Amperometric Chlorine Dioxide Electrode - Features

    • Embedded memory chip accessible via the GF 9950-X Chlorine Controller
    • Quick assembly with DryLoc® connector
    • Integrated temperature element for automatic temperature compensation
    • Separate drive electronics (2650 Electronics), for easy servicing & electrode replacement
  • Cadmium Analyzer | Carl Zeller

    Cadmium Analyzer - Overview

    The Cadmium Analyzer can perform continuous analysis of heavy metals, such as Cadmium (Cd), and many other parameters in water. Technologies employed are colorimetric (photometric) and ion-selective electrodes (ISE). Direct measurements, standard addition, and titration support this ideal measurement strategy. The robust design and high-quality parts of the Cadmium Analyzer guarantee a long lifetime and minimum maintenance efforts. Low consumption of reagents and very high reagent stability ensures person-free operation. Automated calibration and cleaning steps support this goal.

    Cadmium Analyzer - Features

    • Robust design
    • Minimal maintenance
    • Easy handling
    • High accuracy and precision
    • Suitable for mission-critical applications
    • Automated cleaning and calibration

    Datasheet

  • Calcium and Magnesium Analyser | Antojn Bruckner

    Calcium and Magnesium Analyser - Overview

    The Calcium and Magnesium Analyser performs continuous analysis of heavy metals,  Calcium (Ca) and Magnesium (Mg), and many other parameters in water. Technologies employed are colorimetric (photometric) and ion-selective electrodes (ISE). Direct measurements, standard addition, and titration support this ideal measurement strategy. The robust design and high-quality parts of the Calcium and Magnesium Analyzer guarantee a long lifespan and minimum maintenance. Low consumption of reagents and very high reagent stability ensures person-free operation. Automated calibration and cleaning steps.

    Calcium and Magnesium Analyser - Features

    • Robust design
    • Minimal maintenance
    • Easy handling and long life span
    • High accuracy of measurement
    • High precision
    • Suitable for mission-critical applications
    • Automated cleaning, calibration and dilution
    • Can perform complex control tasks via analogue and digital communication
  • Copper Analyzer | Johann H. Schmelzer

    Copper Analyzer - Overview

    The Copper Analyzer performs continuous analysis of metals, such as Copper (Cu), and many other parameters in water. Technologies employed are colorimetric (photometric) and ion-selective electrodes (ISE). Direct measurements, standard addition, and titration support this ideal measurement strategy. The robust design and high-quality parts of the Copper Analyzer  guarantee a long lifespan and minimum maintenance. Low consumption of reagents and very high reagent stability ensures person-free operation. Automated calibration and cleaning.

    Copper Analyzer - Features

    • Robust design
    • Minimal maintenance
    • Easy handling
    • High accuracy and precision
    • Suitable for mission-critical applications
    • Automated cleaning and calibration

    Datasheet

  • Copper and Nickel Analyser | Alban Berg

    Copper and Nickel Analyser - Overview

    The Copper and Nickel Analyser performs continuous analysis of metals, such as Copper (Co) and Nickel (Ni), and many other parameters in water. Technologies employed are colorimetric (photometric) and ion-selective electrodes (ISE). Direct measurements, standard addition, and titration enable this ideal measurement strategy. The robust design and high-quality parts of the Copper and Nickel Analyzer guarantee a long lifespan and minimum maintenance. Low consumption of reagents and very high reagent stability ensures person-free operation. Automated calibration and cleaning. This process analyser was developed and built for the industrial wastewater and drinking water industry. The main advantages are the combined measurement in one step, and the use of non-toxic and non-hazardous reagents.

    Copper and Nickel Analyser - Features

    • Non-dangerous chemistry and reagents
    • Robust design
    • Minimal maintenance
    • Easy handling
    • High accuracy and precision
    • Suitable for mission-critical applications
    • Automated cleaning and calibration

    Datasheet

  • Zinc Analyser | Johann G. Albrechtsberger

    Zinc Analyser - Overview

    The Zinc Analyser can perform continuous analysis of heavy metals, such as Zinc (Zn), and many other parameters in water. Technologies employed are colorimetric (photometric) and ion-selective electrodes (ISE). Direct measurements, standard addition, and titration support the ideal measurement strategy. The robust design and high-quality parts of the Zinc Analyser guarantee a long lifespan and minimum maintenance. Low consumption of reagents and very high reagent stability ensures person-free operation. Automated calibration and cleaning.

    Zinc Analyser - Features

    • Robust design
    • Minimal maintenance
    • Easy handling
    • High accuracy and precision
    • Suitable for mission critical applications
    • Automated cleaning and calibration

    Datasheet

  • Iron Analyzer | Joseph von Eybler

    Iron Analyzer - Overview

    The Iron Analyzer can perform continuous analysis of heavy metals, such as Iron (Fe), and many other parameters in water. Technologies employed are colorimetric (photometric) and ion-selective electrodes (ISE). Direct measurements, standard addition, and titration support this ideal measurement strategy. The Iron Analyzer's robust design and high-quality parts guarantee a long lifespan and minimum maintenance. Low consumption of reagents and very high reagent stability ensures person-free operation. Automated calibration and cleaning.

    Iron Analyzer - Features

    • Non-toxic chemistry !!!
    • Robust design
    • Minimal maintenance
    • Easy handling
    • High accuracy and precision.
    • Suitable for mission-critical applications
    • Automated cleaning and calibration

    Datasheet

  • Lug Style Butterfly Valve | 578

    Lug Style Butterfly Valve - Overview

    The Lug style butterfly valve has all-plastic housing which combines quality and durability. Through the use of fibreglass-reinforced polypropylene, the valve's weight is greatly reduced. This simplifies not only the installation of the valve but also saves on the storage cost.  The valve can be used reliably in highly corrosive applications and is excellent for use with aggressive media. The system allows the exchange of individual system components at any time - quickly and easily, without much effort.  Since the actuation torque is strongly dependent on the internal pressure, type 578 is optimally designed in this area. The maximum nominal pressure is 10 bar on both sides at 20 °C. A further benefit of this is the long life span since the valve is less exposed to wear and tear.

    Lug Style Butterfly Valve - Features

    • Corrosion resistant
    • Stable and Reliable
    • Easy maintenance
    • Long life span
    • Minimal operation torque
    • Can be fitted with an actuator (optional)
    • Lever positioning clearly marked
    • Can be used with electric position indicators (optional)
    • Use as lugged valve with threaded bushes integrated into the housing
    • Lower weight than metallic butterfly valves
    • Low wear and tear: up to 50 % lower operating torque than centric valves
    • Leak-tightness within and without: double, internal axis gasket on both sides
    • Lockable hand lever

    https://www.youtube.com/watch?v=zxaAQxm3Ycg

     

  • Manganese Analyser | Georg C. Wagenseil

    Manganese Analyser - Overview

    The Manganese Analyser can perform continuous analysis of heavy metals, such as Manganese (Mn), and many other parameters in water. Technologies employed are colorimetric (photometric) and ion-selective electrodes (ISE). Direct measurements, standard addition, and titration enable the ideal measurement strategy. The robust design and high-quality parts of the Manganese Analyser guarantee a long lifespan and minimum maintenance. Low consumption of reagents and very high reagent stability ensures person-free operation. Automated calibration and cleaning.

    Manganese Analyser - Features

    • Non-toxic chemistry
    • Robust design
    • Minimal maintenance
    • Easy handling
    • High accuracy and precision
    • Suitable for mission-critical applications
    • Automated cleaning and calibration

    Datasheet

  • Nickel Analyser | Johann J. Fux

    Nickel Analyser - Overview

    The Nickel Analyser can perform continuous analysis of heavy metals, such as Nickel (Ni), and many other parameters in water. Technologies employed are colorimetric (photometric) and ion-selective electrodes (ISE). Direct measurements, standard addition, and titration enable this ideal measurement strategy. The robust design and high-quality parts of the Nickel Analyser guarantee a long lifespan and minimum maintenance. Low consumption of reagents and very high reagent stability ensures person-free operation. Automated calibration and cleaning.

    Nickel Analyser - Features

    • Robust design
    • Minimal maintenance
    • Easy handling
    • High accuracy and precision
    • Suitable for mission-critical applications
    • Automated cleaning and calibration

    Datasheet

  • Iron and Manganese Analyser | Joseph Lanner

    Iron and Manganese Analyser - Overview

    The Iron and Manganese Analyser can perform continuous analysis of metals, such as Iron (Fe) and Manganese (Mn), and many other parameters in water. Technologies employed are colorimetric (photometric) and ion-selective electrodes (ISE). Direct measurements, standard addition, and titration support the ideal measurement strategy. The robust design and high-quality Iron and Manganese Analyser parts guarantee a long lifespan and minimum maintenance. Low consumption of reagents and very high reagent stability ensures person-free operation. Automated calibration and cleaning. This process analyser was developed for the industrial wastewater and drinking water industry. The main advantages are the combined measurement in one measurement step and the use of non-toxic and non-hazardous reagents.

    Iron and Manganese Analyser -  Features

    • Nontoxic chemistry
    • Robust design
    • Minimal maintenance
    • Easy handling
    • High accuracy and precision
    • Suitable for mission-critical applications
    • Automated cleaning and calibration

    Datasheet

  • Portable Water Analyser Series | PMI800SS

    Portable Water Analyser Series - Overview

    The Portable Water Analyser can be paired with a variety of portable electrodes, enabling a variety of measurement parameters such as pH, ORP, Conductivity (convertible Salinity & TDS), Dissolved Oxygen (DO), Turbidity, Suspended solids, Chlorophyll, and Blue-green algae. The connected electrode type is automatically identified. Single-channel and dual-channel configurations are available. It is comfortable to operate because of its ergonomic design and allows for quick and convenient testing.

    Portable Water Analyser Series  - Features

    • IP67 protection rating
    • 3.5-inch color screen display
    • Easy to use interface and menu
    • Ergonomic design for holding
    • Non-slip hand strap
    • Data storage space 8G
    • Data export via USB interface
    • Built-in rechargeable battery
    • Charging directly via USB
    • Automatically identifies sensor type and automatically adapts
    • Parameter can be set and calibrated on sensors