Wafer Electromagnetic Flow Meter | RWEM/W

Wafer Electromagnetic Flow Meter | RWEM/W

Wafer Electromagnetic Flow Meter  – Overview

This wafer electromagnetic flow meter uses a new generation of special high-quality linings and mirror-polished PFA linings, making it suitable for the measurement of viscous pulp and gypsum slurry. Its detachable electrode makes maintenance more convenient. The product is based on Faraday’s law of electromagnetic induction, used to measure the conductance greater than 20 μS/cm volume of conductive liquid flow. Not only can it measure the general volume of conductive liquid flow, but can also measure strong acids, alkalis, corrosive liquids and mud, pulp, etc.

Wafer Electromagnetic Flow Meter  – Features

  • Size: DN25mm-DN200mm
  • Nominal Pressure: 1.6Mpa
  • Accuracy: ±0.5%(Standard), ±0.3%(optional) ±0.2%(optional)
  • Liner: PTFE, FEP, PFA
  • Measuring Range: 0.5m/s-15m/s
  • Suitable for confined spaces
  • Fits all flanges like ANSI, DIN, and JIS
  • Stainless steel
  • Very economical
  • Lightweight for easy installation
  • Multiple output signals  RS485/HART/Profibus

Description

Wafer Electromagnetic Flow Meter | RWEM/W

Table 1: Wafer Electromagnetic Flow Meter Specification

Size DN25mm-DN200mm
Nominal Pressure 1.6Mpa
Accuracy ±0.5%(Standard)
±0.3% or ±0.2%(Optional)
Liner PTFE, FEP, PFA
Electrode SUS316L, Hastelloy B, Hastelloy C,
Titanium, Tantalum, Platinum-iridium
Structure Type Integral type, remote type, submersible type, ex-proof type
Medium Temperature -20~+60degC (Integral type)
Remote type (PTFE/PFA/FEP) -10~+160degC
Ambient Temperature -20~+60degC
Ambient Humidity 5~90%RH(relative humidity)
Measuring Range 0.5m/s-15m/s
Conductivity >5us/cm
Protection Class IP65 (Standard); IP68 (Optional for remote type)
Output Signal 4-20mA, pulse/frequency, relay
Communication MODBUS RTU RS485, HART (Optional), GPRS/GSM (Optional)
Power Supply  AC220V(Can be used for AC85-250V)
DC24V(Can be used for DC20-36V)
DC12V(Optional),Battery Powered 3.6V(Optional)
Power Consumption <20W
Explosion Proof ATEX Exdll T6Gb

Table 2: Wafer Electromagnetic Flow Meter Flow Range

Size Flow Range & Velocity Table
(mm) 0.1m/s 0.2m/s 0.5m/s 1m/s 4m/s 10m/s 12m/s 15m/s
25 0.177 0.353 0.883 1.766 7.065 17.663 21.2 26.494
32 0.289 0.579 1.447 2.894 11.575 28.938 34.73 43.407
40 0.452 0.904 2.261 4.522 18.086 45.216 54.26 67.824
50 0.707 1.413 3.533 7.065 28.260 70.650 84.78 105.98
65 1.19 2.39 5.97 11.94 47.76 119.40 143.3 179.10
80 1.81 3.62 9.04 18.09 72.35 180.86 217.0 271.30
100 2.83 5.65 14.13 28.26 113.04 282.60 339.1 423.90
125 4.42 8.83 22.08 44.16 176.63 441.56 529.9 662.34
150 6.36 12.72 31.79 63.59 254.34 635.85 763.0 953.78
200 11.3 22.61 56.52 113.04 452.16 1130.40 1356 1696
Suggest Velocity: 0.5m/s – 15m/s

Table 3: Wafer Electromagnetic Flow Meter Size

Diameter φA(mm) φB(mm) φC(mm) H(mm) L(mm)
DN25 60.5 68 22 295 100
DN32 68.5 76 30 303 100
DN40 74.5 89 36 316 100
DN50 90.8 102 48 329 100
DN65 109.8 119.5 64 346.5 150
DN80 120.7 133 77 360 150
DN100 150.2 159 102 386 150
DN125 174.8 190 121 417 200
DN150 204.7 219 147 446 200
DN200 257.8 273 207 500 200

Wafer Electromagnetic Flow Meter | RWEM/W

Brand

Royce Water Systems

Reviews

There are no reviews yet.

Be the first to review “Wafer Electromagnetic Flow Meter | RWEM/W”