Ultrasonic Flow Sensor Heat Meter | GF U3000

Ultrasonic Flow Sensor Heat Meter | GF U3000

Ultrasonic Flow Sensor Heat Meter – Overview

The U3000 provides various options for high-accuracy measurement for permanent ultrasonic Clamp-On flow metering. Options are available for high-accuracy measurement, power, communication, pipe dimension, data storage & export. It can be customised to almost any application need. The type U3000 V2 Heatmeter (HM) is an ultrasonic permanent clamp-on heatmeter / energy meter / BTU meter. Additionally, it is equipped with Pt100 temperature sensors to calculate the energy of a heat-exchanging system. The ‘Clamp-On’ concept allows for easy installation without process disruption. Compact, robust and reliable. Designed for long-term use in industrial applications. It can be used on PVDF, ABS, PVC, CPVC, PP, PE, PB-Instaflex, iron and steel pipes. Processes can be monitored directly by a higher-level system via 4 to 20 mA, Modbus, pulse or frequency output.

Ultrasonic Flow Sensor Heat Meter  – Features

  • Large, easy-to-read graphic display with backlighting
  • Easy to install
  • ‘Clamp-On’ design
  • Datalogger option (up to 100 million data points)
  • USB port for easy data export
  • Analog, digital Modbus, pulse & alarm outputs
  • Reynolds number correction
  • Compatible with almost all pipe types
  • Automatic energy calculation with two Pt100 temperature sensors (HM version)

Description

Ultrasonic Flow Sensor Heat Meter | GF U3000

Specifications
General
Measuring Method Ultrasonic runtime measurement
Flow range 0.1 m/s – 20 m/s
Accuracy Pipes > DN75 ± 0.5 % – 3 % of the measured value for flow throughput rates > 0.2 m/s
Pipes DN13 – DN75 ± 0.3 % of the measured value for flow throughput rates > 0.2 m/s
Repetition accuracy ± 0.5 % of the measured value for flow or ± 0.02 m/s depending on which value is larger
Response time < 500 ms, depending on pipe diameter
Selectable flow units Velocity m/s, ft/s
Volume l/s, l/min, l/h, gal/min, gal/h, USgals/min, USgals/h, Barrel/h, Barrel/day, m³/s, m³/min, m³/h
Selectable totaliser units Liters, m³, gallons, US gallons, barrels
Totaliser 12 digits
Menu languages EN, DE, FR, RU, SE, IT, SP, P, NO, DEN
Temperature sensors (Heatmeter types only)
Operating temperature 0 °C to +50 °C
Storage temperature -10 °C to +60 °C
Pipe wall temperature -20 °C to +85 °C
Accuracy Pt100 Class B 4-wire
Resolution 0.1 °C (0.2 °F)
Humidity during operation Max. 90 % relative humidity at +50 °C (122 °F)
Environment
Operating temperature -20 °C to +50 °C
Storage temperature -25 °C to +75 °C
Pipe wall temperature -20 °C to +135 °C
Humidity during operation Max. 90 % relative humidity at +50 °C (122 °F)
Suitable pipe types
Pipe material PVDF-SYGEF, PP-PROGEF, PE-ELGEF, PB-INSTAFLEX,
ABS, PVC-U/PVC-C, construction steel, cast iron, stainless steel, copper
Pipe dimensions [d] 13 – 2’000 mm
Pipe wall thickness 1 – 75 mm
Pipe coating Possible Materials: rubber, glass, concrete, epoxy, steel
Pipe coating thickness 0 – 25 mm
Electronics
Power supply 12 V to 24 V AC/DC, 1A max. or 86 V to 264 V AC (47 Hz to 63 Hz)
Power consumption max. 10,5 W
Outputs (output options depending on type)
Analog output Range 4 – 20 mA, 0 – 20 mA, 0 – 16 mA
Resolution 0.1 % of full scale
Load max. 620 Ω
Insulation 1,500 V opto-isolated
Alarm current Adjustable between 0 – 26 mA
Pulse output Type 3x Opto-isolated MOSFET volt free contact (NO/NC)
Options Flow totals, energy (HM version only), loss of signal, low flow alarms
Pulse sequence Volumetric mode: 1 to 50 pulses/sec user-programmable Frequency mode: 200Hz max. pulse frequency
Pulse width 50 ms standard value, 3 to 99 ms user-programmable
Max. Voltage 48 V
Max. Current 150 mA
Isolation >110 V AC/DC
Modbus output Format RTU
Baud Rate 1200, 2400, 4800, 9600, 19200, 38400
Data-Parity-StopBits 8-None-2, 8-None-1, 8-Odd-2, 8-Even-1
Standarads PI–MBUS–300 Rev. J
Physical Connection RS485
USB interface (Optional Protocol Supports full speed (12Mbits/sec) data connection
Software USB driver software is provided with the package
Connector Mini USB
Datalogger (optional)
Data Logged
Application details, time, date, flowrate, forward total, reverse total, flow velocity, flow side temperature, return side temperature, temperature difference, power, total energy, signal quality, signal SNR, signal status
Number of data points 100 million
Number of data sets 12
Number of data points per set No limit
Programmable capture rate 5 s – 1 hour
Start/stop Manual or time-controlled
Data download USB interface
Transducer Sets
Type A 13 to 114 mm (1/2 inch to 4.5 inch) pipe OD (2MHz)
Type B 50 to 2000 mm (2 inch to 40 inch) pipe OD (1MHz)
Enclosure and Display
Material ABS and aluminium
Dimensions 230 x 180 x 120 mm
Weight 1.2 kg
Keypad 15 key tactile feedback membrane keypad
Display Type 240 x 64-pixel graphic display, high contrast black-on-white, with backlight.
Viewing angle Min. 30°, typically 40°
Active surface 127 x 34 mm
Protection class IP 65
Standards/approvals
CE, RoHS compliant
Safety BS EN 61010-1:2010
EMV BS EN 61326-1:2013 BS EN 61326-2-3:2013
Environmental BS EN 60068-1:2014
BS EN 60068-2-1:2007 BS EN 60068-2-2:2007