Online Nitrate Sensor Nitro::lyser VS3 Overview

The Online Nitrate Sensor Nitro::lyser VS3 is ideal for the measurement of nitrate concentrations and turbidity/solids concentrations too. The nitrate concentration displayed is not sensitive to cross-influences from other substance groups such as organic carbon or total solids. Applications range from (ultra) pure water in the μg/l range up to industrial wastewater in the g/l range.

Nitro::lyser VS3 Features

  • Nitro::lyser™ II monitors 2 of the following parameters: Turbidity, TSS, TS, NO3-N and NO3
  • Measuring principle: UV-Vis spectrometry over the total range (190-750 nm)
  • Webserver onboard – IoT enabled, no user software is needed to configure the probe
  • Communicates directly with your mobile device via WLAN
  • Choose exactly the parameters you want to measure – unlimited number of parameters possible
  • 8 GB onboard memory – capacity for logging data for many years
  • Improved optical performance – revolutionary precision
  • Fast measurement interval – every 10 seconds
  • Extremely power-efficient – sleep mode for low energy consumption
  • Multiparameter probe with 1 mm, 5 mm, or 35 mm optical path length, ideal for wastewater, surface water, and drinking water
  • Long term stable and maintenance-free in operation
  • Factory precalibrated, local multi-point calibration possible
  • Automatic cleaning with compressed air or brush/ruck::sack

Drinkwater & Surface water Datasheet
Wastewater Datasheet

Description

Online Nitrate Sensor Nitro::lyser VS3 Technical Specifications

Measuring principle UV-V is spectrometry 190 – 750 nm


Measurement interval 10 sec (configurable)


Automatic cross sensitivities Turbidity | Solids | Organic substances


Precalibrated ex-works All parameters


Accuracy standard solution (>1 mg/l) NO3-N : +/- 2% +1/OPL [mg/l]*
COD-KHP : +/-2% +10/OPL [mg/l]*
(* OPL – Optical Path Length in mm)


Access to raw signals No


Reference standard Distilled Water


Integrated Temperature Sensor 0 – 45 °C


Temperature Sensor Resolution 0.1 °C


Integration via Con::cube V3
Con::nect V3
Con::lyte V5 (D-320-pro2)
Adapter cable (C-32-V3)


Power supply 10 – 18 VDC


Power consumption (typical) 3 W


Power consumption (sleep mode) 60 mW


Power consumption (max.) 20 W


Interface to s::can terminals M12 RSTS 8Y | IP67
RS485 

Ethernet


Interface to third party terminals Con::nect V3 incl. Modbus RTU
REST API
Modbus TCP|IP


Digital interface (for cleaning devices) 1 digital in
1 digital out


Network connection 100 Base-T Ethernet | WLAN


Status information RGB LED ring


Additional Specifications

Internal sensors Supply voltage sensor
Tilt sensor
Rotation sensor


Cable length 1 m fixed cable (-010) |
7.5 m fixed cable (-075) |
15 m fixed cable (-150)


Cable type PU jacket


Housing material Stainless steel 1.4404


Window material OPL 5 and 1 mm: sapphire
OPL 35 mm: fused silica (UV-grade)


Weight (min.) 3.4 kg (incl. cable)


Dimensions (Ø x l) OPL 35 mm :
44 x 473 mm | 517.5 mm
OPL 5 mm :
44 x 457 mm | 501.5 mm
OPL 1 mm:
44 x 453 mm | 497.5 mm


Operating temperature 0 – 45 °C


Operating pressure 0 – 3 bar


High-pressure specification 10 bar


Installation / mounting Submersed | in a flow cell


Flow velocity 3 m/s (max.)


Mechanical stability 30 Nm


Ingress protection class IP68


Automatic cleaning Media: compressed air |
auto brush
Permissible pressure : 3 – 6 bar


Storage temperature -10 – 65 °C


Conformity – environmental testing EN 60721-3


Conformity – EMC EN 61326-1


Conformity – RoHS 2 EN 50581


Standard warranty 2 years


Extended warranty (optional) 3 years

Drinking-Water Parameters

Surface water
parameter
turbidity
[NTU/FTU]
NO3-N
[mg/l]
NO3
[mg/l]
part number
nitro::lyserTM II
(2 parameters, 5 mm OPL)
min. 0 0 0 G3-N2-R-05-NO-xxx
max. 1400 100 460

 

Groundwater
parameter
turbidity
[NTU/FTU]
NO3-N
[mg/l]
NO3
[mg/l]
part number
nitro::lyserTM II
(2 parameters, 35 mm OPL)
min. 0 0 0 G3-N2-G-35-NO-xxx
max. 170 20 88

 

Drinking water
parameter
turbidity
[NTU/FTU]
NO3-N
[mg/l]
NO3
[mg/l]
part number
nitro::lyserTM II
(2 parameters, 35 mm OPL)
min. 0 0 0 G3-N2-D-35-NO-xxx
max. 170 20 88

Wastewater Parameters

Municipal WWTP influent & sewer
parameter
TSS
[mg/l]
NO3-N
[mg/l]
NO3
[mg/l]
part number
nitro::lyserTM II
(2 parameters, 1 mm OPL)
min. 0 0 0 G3-N2-I-01-NO-xxx
max. 8000 100 460
nitro::lyserTM II
(2 parameters, 5 mm OPL)
min. 0 0 0 G3-N2-I-05-NO-xxx
max. 1200 16 70

 

Municipal WWTP aeration
parameter
TS
[g/l]
NO3-N
[mg/l]
NO3
[mg/l]
part number
nitro::lyserTM II
(2 parameters, 1 mm OPL)
min. 0 0 0 G3-N2-A-01-NO-xxx
max. 20 26 110

 

Municipal WWTP effluent
parameter
TSS
[mg/l]
NO3-N
[mg/l]
NO3
[mg/l]
part number
nitro::lyserTM II
(2 parameters, 5 mm OPL)
min. 0 0 0 G3-N2-E-05-NO-xxx
max. 600 45 190

Brand

s::can

s-can logo s::can

Additional information

Option

Drinking-Water, Surface Water, Ground Water, Wastewater – Municipal Influent & Sewer, Wastewater – Municipal Effluent, Wastewater – Aeration

Reviews

There are no reviews yet.

Be the first to review “Online Nitrate Sensor | Nitro::lyser VS3”