Tag: Liquid Flow Measurement

Liquid Flow Measurement

  • Flow Wet-Tap Valve | Signet 3519

    Flow Wet-Tap Valve - Overview

    This Valve provides a quick method of removing a sensor from the pipe under specified operating pressures. The PVC and stainless steel design of the Wet-Tap makes it resistant to corrosion and chemical attack by acids, alkalies, salt, and a number of other harsh chemicals. It mounts directly onto standard Signet installation fittings. It consists of a flange and support plate that threads onto the pipe fitting insert, and a PVC ball valve through which an extended length sensor is inserted into the pipe.

    Flow Wet-Tap Valve - Features

    • Highly versatile
    • Chemically compatible with many liquid process applications
    • Corrosion and chemical attack-resistant
    • Quick solution to remove/ insert sensor
  • High Pressure Liquid Flow Meter | DS1171

    High Pressure Liquid Flow Meter - Overview

    This metal-bodied flow meter functions using a spring-loaded orifice moving over a tapered cone, creating a variable area flow meter. The flow is indicated by a magnetic follower ring under a scale on an external glass tube. The flow reading is independent of viscosity up to 200 cs. Suitable for water or oil.

    High Pressure Liquid Flow Meter - Features

    • Works in any orientation
    • Pressure up to 350 bar (5000 psi)
    • Accuracy ±5% FSD
    • Repeatability ±1% FSD
    • Direct reading
    • Relatively insensitive to viscosity changes
    • Oil or water calibrated
  • Turbine Flow Sensor | Signet 2100

    Turbine Flow Sensor - Overview

    The Turbine Flow Sensor is engineered specifically for small pipe diameters. It provides accurate readings in : 0.3 to 3.8 lpm and 3 to 38 lpm. The injection-molded PVDF body and ceramic bearings provide excellent chemical compatibility and long service. Union piping and tubing connections along with removable NEMA 4X electronics allow for easy assembly and field replaceability. It can be used with DN8, DN10 , DN15 tubing, or DN15 piping for simple installation. End connections are available in PVDF for hose barbs, fusion socket or IR/butt fusion, and in PVC for socket or NPT thread.

    Turbine Flow Sensor - Features

    • Operating range of 0.38 to 38 lpm (0.10 to 10 U.S. gpm)
    • Easy assembly
    • Easy field replaceability
    • Non-magnetic turbine
    • Union ends for various connector types
    • End connector kits for rigid or flexible tubing or DN15 pipe
    • Superior chemical compatibility -PVDF & ceramic wetted parts
    • For both clear and opaque fluids
    • Small and compact design
    • 4.6 m cable
    • Removable electronics that install from either side of the sensor
  • Customisable Mag x2 Flowmeter | DS1172

    Customisable Mag x2 Flowmeter - Overview

    The Mag X2 allows you to build and configure your flowmeter based on your specifications and needs. It is a flexible device suitable for most applications. Ranging from the most simple applications where readings are checked visually, to the most demanding that require a highly technical solution such as GPRS or TCP/IP communication. The basic configuration consists of the transmitter including only display and buttons to guarantee the lowest price. The more advanced configurations can be added to the basic configuration. This includes outputs, communications or data logging according to each application requirement. These features are added by extra modules which can be freely installed and removed from the main board in seconds.

    Customisable Mag x2 Flowmeter - Features

    • Accuracy ±0.2% (0.5 to 10 m/s) of actual values
    • Bi-directional measurement
    • GPRS Wireless communication system which allows full control of the flowmeter
    • 1 compact and 3 remote configurations available
    • Real-time clock included in the basic transmitter unit
    • Sizes available from 10mm to 1000mm
    • Current 4–20mA output available
    • Auto-cleaning electrodes intelligent sensor design
    • 4 electrodes: 3rd and 4th electrode for earthing and empty pipe detection
    • Automatic self-diagnostic tool for the sensor
    • Graphic display with 6 touch buttons included
    • Multi-language menu
    • BLUETOOTH as a communication option
    • Possible to connect via Internet
    • GSM-SMS communication
    • RS232, RS485 and USB communications available
    • Easily installed or removed
    • Data logging on a standard Micro Secure Digital card
    • Connections available: DIN, ANSI, JIS, wafer, Tri-clamp, ANSI 11851; others on request
    • Liner materials available: Hard rubber, PTFE, PFA, soft rubber
    • Electrode material stainless steel standard. Hastelloy C, tantalum, titanium & platinum available
    • IP68 sensor protection available for remote installations
    • IP67 protection when using RS485, Bluetooth, GPRS or TCP/IP communication, data downloading & communication
    • Temperature sensor
    • Automatic temperature compensation of the sensor
    • Pulse module available: Open collector output included
    • Power supply options: 90–250VAC +/- 10%, 50–60Hz, 24VDC or 12VDC
  • Metal Tube Flowmeters | SC250

    Metal Tube Flowmeters - Overview

    This variable area, high-performance measurement flowmeter, is suitable for use in extreme working conditions. Can be used in liquid or gas flow measurement. Applications include water treatment plants, pulp & paper and food industries; pharmaceutical, chemical and petrochemical industries; power plants and nuclear-generating plants; heating and cooling circuits; saturated steam circuits; oven treatments and control of gas burners.

    Metal Tube Flowmeters - Features

    • Metallic tube with a robust construction
    • Indication using magnetic coupling
    • High-performance measurement in extreme working conditions
    • High resistance to corrosion
    • Low-pressure drop
    • Damping mechanism to avoid float bounces in gas and steam applications
  • Metal Tube Purge Flowmeter | Platon DS1210

    Metal Tube Purge Flowmeter - Overview

    Ideal for liquid or gas flow monitoring on small lines in purging, mixing or sampling systems. It uses a stainless steel tapered tube to create a variable area flowmeter. The magnetically coupled pointer shows flow rate on an external scale. Metal Tube Purge Flowmeters are used where the higher integrity offered by a metal flow tube is important, or where conventional glass flow tubes are not allowed in the process. The meters are available with inline (API) or rear-facing (APT) screwed connections. For fine flow rate adjustment, the APV model has an integral multi-turn needle valve. Scales are individually produced to show the actual fluid flow for the process fluids and conditions relevant. The units are suitable for flush mounting in a control panel, using a simple mounting kit. Standard units require no electrical connection.

    Metal Tube Purge Flowmeter - Features

    • For high integrity of high-pressure duty
    • Standard units require no electrical connection
    • Suitable for flush panel mounting
    • Scaled for specific process conditions

     

  • Platon Safety Housed GU VA Flow Meter | DS1111

    Platon Safety Housed GU VA Flow Meter - Overview

    Type GU are glass tube Variable Area Flowmeters for the direct display of liquid or gas flow rate. It has a robust rigid frame which is suitable for mounting directly into plant pipework, protecting the glass tube from pipework stress and random plant damage. The safety Perspex window gives good flow visibility whilst protecting the operator. A safety blowout disc on the rear of the housing provides a relief vent for process fluids, in case of glass tube damage. Glass tube VA flowmeters are simple and reliable in operation, and instantaneous in response. They offer flow visualisation to the operator, and the float rotation confirms correct meter performance. Standard tubes and floats offer low line pressure loss and a high resolution 100mm linear scale, fused into the glass tube. Fluid flows vertically upward through the tapered glass tube which causes the float to rise to an equilibrium position. Flow rate is measured on the scale of the flow tube, along the top edge of the float. The borosilicate glass tubes are individually scaled according to customers' requirements, and individually flow calibrated.

    Platon Safety Housed GU VA Flow Meter - Features

    • Safety housed for operator protection
    • Site interchangeable 140mm flow tubes
    • Robust construction
    • Instant flow rate visual indication
    • Suitable for installation in unsupported pipework
    • Flow tube scaled for any gas and most liquids
  • Rotor-X Paddlewheel Flow Sensors | Signet 2536

    Rotor-X Paddlewheel Flow Sensors - Overview

    These simple-to-install Paddlewheel Flow Sensors are known for their reliable performance. They are highly repeatable, rugged sensors that offer exceptional value with virtually no maintenance. The 2536 has a process-ready open collector signal with a wide dynamic flow range of 0.1 to 6 m/s. The sensor measures liquid flow rates in full pipes and can be used in low-pressure systems. The Signet 2536 sensors are offered in a variety of materials for a wide range of pipe sizes and insertion configurations. Material choices include PP and PVDF making this model highly versatile and chemically compatible with many liquid process solutions. Sensors can be installed in DN15 to DN900 pipes (except the PVC versions, which can be installed in DN15 to DN100), using Signet’s comprehensive line of custom fittings. These custom fittings include tees, saddles, and weldolets, to seat the sensor to the proper insertion depth into the process flow. The sensors are also offered in configurations for wet-tap installation requirements.

    Rotor-X Paddlewheel Flow Sensors - Features

    • Operating range 0.1 to 6 m/s
    • Wide turndown ratio of 66:1
    • Open-collector output
    • Highly repeatable output
    • Simple, economical design
    • Installs into pipe sizes DN15 to DN900
    • PVC DN15 to DN100 for concentrated Sodium Hypochlorite 12.5% applications
    • High resolution and noise immunity
    • Test certificate included for -X0, -X1
    • Chemically resistant materials
  • Adjustable Liquid Flow Switch | DS1433 Platon

    Adjustable Liquid Flow Switch - Overview

    This flow switch uses a spring-loaded variable orifice flow meter technique. The sensor can be installed at any angle and can operate at high pressures and temperatures. The moving element trips an external reed sensor which can be adjusted along a flow scale.

    Adjustable Liquid Flow Switch - Features

    • High pressures and temperatures
    • High switch capability
    • Compact
    • Good repeatability
    • Dirt-resistant
    • Hermetic separation of mechanical and electrical components
  • Adjustable Liquid Paddle Switch | DS1435

    Adjustable Liquid Paddle Switch - Overview

    These paddle flow switches are simply mounted in a horizontal flow line, through a 1" BSP connection for liquid flow alarms at site adjustable flow rates. The vane is selected or cut to suit the pipe size.

    Adjustable Liquid Paddle Switch |- Features

    • Suitable for 40mm to 200mm pipe
    • Good repeatability
    • Low-pressure loss
  • Plain Flow Indicator | DS1941

    Plain Flow Indicator - Overview

    This is suitable for visual checks on the flow, presence, colour and condition of a liquid. Thanks to the plain spout cast body, it can be used where there is intermittent flow, partially filled pipes or entrained air.  A special version made with borosilicate glass is available for use with steam and condensate, ensuring good long-term visibility.

    Plain Flow Indicator - Features

    • Plain spout cast in the body
    • Special version available for steam and condensate
    • Good long-term visibility
    • Ideal for visual checks on flow, presence, colour, and condition

     

     

  • Screwed Metal Tube VA Flowmeter | Platon DS1221

    Screwed Metal Tube VA Flowmeter - Overview

    This flowmeter is ideal for industrial use as an alternative to large glass tube flowmeters. Suitable for gas or liquid flow measurement at high pressures and temperatures, where the fluids are opaque or dark-coloured. It also provides high operational security for dangerous or toxic materials. Models GMTB and GMTS are brass or Stainless Steel tube flowmeters with female screwed connections. With 1/2”,1” and 2” BSP/NPT threaded fittings standard. The VA meter principle used in the Platon GMT flowmeter measures the position of a float in a precision-machined tapered tube. The float rises with the flow up the taper until the upthrust from the flow balances with the weight of the float. A magnet, electron beam welded into the float casing, drives the external meter indication over a 100mm scale typically displaying a 10:1 flow range. Options available on the GMTB/GMTS include (GMTA) flow alarm outputs for high or low adjustable set points and electronic 4-20mA flow transmitter (GMTX) outputs. All of these are available with CENELEC approval. All units are calibrated for the specific line conditions or fluid involved.

    Screwed Metal Tube VA Flowmeter - Features

    • Economic construction
    • BSP/NPT Screwed end fitting
    • Brass or Stainless Steel
    • Wide flow ranges
    • Sizes 15, 25, 50mm. 1/2”, 1”, 2” bore
    • Integral damping on gas flow lines
    • Local indication
    • Calibration for wide range of gases and liquids
    • Optional electronic outputs
  • Electromagnetic Flow Meter | FLO300

    Electromagnetic Flow Meter- Overview

    The Electromagnetic Flow Meter can measure liquids with a minimum electrical conductivity. Various types of lining materials are available to suit chemically aggressive liquids or suspended solids. The soft rubber lining ensures resistance to abrasion caused by water with suspended solids. This electromagnetic flow meter can be used in all industries for liquid flow measurement from DN10 to DN1600.

    Electromagnetic Flow Meter - Features

    • Suitable for Liquids with Suspended Solids
    • Wide Range DN10-DN1600mm
    • Fully Bi-Directional Measurement
    • Extreme Reliability
    • High Precision
    • No Moving Parts
    • No Pressure Losses
    • Extended Measuring Range
    • Less Affected by Pressure, Temperature, Density and Viscosity of Liquid