Insertion Type Electromagnetic Flow Meter -Overview

The insertion type electromagnetic flow meter provides an economical option for large pipeline flow measurement while retaining the advantages of the common magnetic flow meter. It can be used for pipe sizes between DN100mm and DN3000mm. It can be easily installed due to its hot-tap structure. The main advantage of using an electromagnetic flow meter is that it has no moving parts. It requires very little maintenance.  This insertion type electromagnetic flow meter consists of an ABS or Polypropylene electromagnetic sensing probe mounted on the end of a support rod.

Insertion Type Electromagnetic Flow Meter – Features

  • Pipe sizes between DN100mm and DN3000mm
  • Hot-tap structure
  • Easy installation
  • No moving parts
  • Virtually no maintenance
  • Economical
  • Submersible option
  • Various outputs available

Description

Insertion Type Electromagnetic Flow Meter | RWEM/C

Table 1 : Insertion Type Electromagnetic Flow Meter Main Performances Parameters

Size DN100mm-DN3000mm
Nominal Pressure 1.6Mpa
Accuracy 1.5%
Probe ABS, Polyurethane
Electrode SUS316L, Hastelloy B, Hastelloy C
Structure Type Integral type, remote type
Medium Temperature -20~+80degC
Ambient Temperature -20~+60degC
Ambient Humidity 5~100%RH(Relative humidity)
Measuring Range Max 15m/s
Conductivity >5us/cm
Protection Class IP65(Standard); IP68(Optional for remote type)
Process Connection 2” Thread(Standard), 2” Flange(Optional)
Output Signal 4-20mA/Pulse
Communication RS485(Standard), HART(Optional), GPRS/GSM(Optional)
Power Supply AC220V(Can be used for AC85-250V)
DC24V(Can be used for DC20-36V)
DC12V(Optional), Battery powered 3.6V(Optional)
Power Consumption <20W
Alarm Upper Limit Alarm / Lower Limit Alarm
Self-diagnosis Empty Pipe Alarm, Exciting Alarm
Explosion Proof ATEX

 

Table 2 : Insertion Type Magnetic Flow Meter Electrode Material Selection

Electrode Material Applications & Properties
SUS316L Applicable to industrial/municipal water, wastewater and low corrosive mediums.
Widely used in petroleum, chemical industries.
Hastelloy B Strong resistance to hydrochloric acids below the boiling point.
Resist against oxidable acids, alkali and non-oxidable salts. For instance, vitriol, phosphate, hydrofluoric acids, and organic acids.
Hastelloy C Exceptional resistance to strong solutions of oxidizing salts and acids. For example, Fe+++, Cu++, Nitric acids, mixed acids

 

Table 3 : Insertion Type Magnetic Flow Meter Flow Range

Size Flow Range & Velocity Table
(mm) 0.1m/s 0.2m/s 0.5m/s 1m/s 4m/s 10m/s 12m/s 15m/s
100 2.83 5.65 14.13 28.26 113.04 282.6 339.1 423.9
125 4.42 8.83 22.08 44.16 176.63 441.56 529.9 662.34
150 6.36 12.72 31.79 63.59 254.34 635.85 763 953.78
200 11.3 22.61 56.52 113.04 452.16 1130.4 1356 1696
250 17.66 35.33 88.31 176.53 706.5 1766.25 2120 2649
300 25.43 50.87 127.2 254.34 1017 2543.4 3052 3815
350 34.62 69.24 173.1 346.19 1385 3461.85 4154 5193
400 45 90 226.1 452 1809 4522 5426 6782
450 57 114 286.1 572 2289 5723 6867 8584
500 71 141 353.3 707 2826 7065 8478 10598
600 102 203 508.7 1017 4069 10174 12208 15260
700 138 277 692.4 1385 5539 13847 16617 20771
800 181 362 904.3 1809 7235 18086 21704 27130
900 229 458 1145 2289 9156 22891 27469 34336
1000 283 565 1413 2826 11304 28260 33912 42390
1200 407 814 2035 4069 16278 40694 48833 61042
1400 554 1108 2769 5539 22156 55390 66468 83084
1600 723 1447 3617 7235 28938 72346 86815 108518
1800 916 1831 4578 9156 36625 91562 109875 137344
2000 1130 2261 5652 11304 45216 113040 135648 169560
2200 1368 2736 6839 13678 54711 136778 164134 205168
2400 1628 3256 8139 16278 65111 162778 195333 244166
2600 1910 3821 9552 19104 76415 191038 229245 286556
2800 2216 4431 11078 22156 88623 221558 265870 332338
3000 2543 5087 12717 25434 101736 254340 305208 381510
Remark:Suggest flow velocity range 0.5m/s – 15m/s