  • pH and ORP Electrodes | 2724, 2726, 2725

    Price range: R8,121.00 through R18,103.00

    pH and ORP Electrodes - Overview

    The Georg Fischer 2724-2726 pH and ORP Electrodes feature a patented reference electrode design and use the unique foul-proof DryLoc® connector. The large area PE reference junction and pathway are constructed to increase the total reference effectiveness and ensure long service life.

    The DryLoc connector with corrosion-resistant gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensor electronics. The robust Ryton® threaded sensor body and choice of flat pH, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications.

    There are two optional sensing versions, HF and LC, available. The quick temperature response is available in either a PT1000 or 3 KΩ temperature sensor and allows compatibility with all Georg Fischer pH/ORP instruments. The 2724-2726 electrodes are general-purpose sensors ideal for a wide range of applications. The sensors incorporate ¾” NPT or ISO 7-1 R¾ thread for installation into standard pipe tees. They can also be mounted directly into Georg Fischer's standard fittings.

    pH and ORP Electrodes - Features

    • Wetted Materials: Ryton, UHMW polyethylene, FKM, glass
    • Connection: Durable DryLoc® with gold-plated connections
    • Compatible Preamp/Sensor Electronics: 2750 and 2760
    • Compatible Instruments: Use the 2760 preamplifier with the Georg Fischer 8750; Use the 2750 sensor electronics with the Georg Fischer 8900, 9900 or 9950 instruments
    • Additional Features: HF and LC options available
    • In-line Mounting styles:  Standard 3/4 inch or ISO threaded fittings
    • Submersible mounting: Available using the back of the preamplifier or sensor electronics
  • Conductivity Sensor System | 2850

    Price range: R22,439.00 through R31,256.00

    Overview of Conductivity Sensor 2850

    The Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations  for maximum installation flexibility. The universal mount version is for pipe, wall, or tank mounting and enables single or dual (digital versions only) inputs using any standard Signet conductivity/resistivity sensor. The threaded j-box version can be used with these same Signet sensors for submersible sensor mounting. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0,10.0 or 20.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 400,000 μS or a resistivity range of 18.2 MΩ to 10 kΩ.

    All 2850 units are available with a digital (S3L) output, or  a single 4 to 20 mA. The digital (S3L) output version can be paired with the 9900 or 9950 Transmitter to extend the distance between the measuring points to 120 m (400 ft).

    The 8900 Multi-Parameter Controller allows for up to six 2850 (S3L) output conductivity sensors to be used with the Signet 8900 Multi-Parameter Controller. All 2850 units are built with NEMA 4X/IP65 enclosures which allow output wiring connections with long cable runs of up to 305 m (1,000 ft).

    The two-wire 4 to 20mA output version is available with eight 4 to 20 mA output ranges for each electrode cell constant. Each range can be inverted and is field selectable.

    EasyCal is a standard feature that automatically recognizes conductivity test solution values for simple field calibration. A certification tool is available for validation of the sensor electronics according to USP requirements.

    Conductivity Sensor system Features

    • Test certificate supplied with all sensors
    • Custom cell constant programmed into the electronics
    • Integral mount systems for quick and easy installation
    • Compact design for maximum installation flexibility
    • Extends the distance between the measuring point and the 9900 Transmitter to 120 m (400 ft)
    • Digital (S3L) interface or two-wire 4 to 20mA output
    • EasyCal with automatic test solution recognition
    • For use with ALL Signet conductivity electrodes
  • Magmeter Flow Sensor | 2551

    Price range: R32,897.00 through R89,766.00

    Magmeter Flow Sensor - Overview

    This insertion magnetic flow sensor features no moving parts. It is available in corrosion-resistant materials to provide long-term reliability with minimal maintenance costs. Material options include PP with stainless steel, PVDF with stainless steel, PVDF with Hastelloy-C, or PVDF with Titanium. These versatile, simple-to-install sensors deliver accurate flow measurements for a wide range of pipe sizes ranging from DN15 to DN900 (½ to 36 inches), making them suitable for various applications. These Magmeters offer frequency/digital (S3L) or 4 to 20 mA output options. Both are available on the blind and display versions. The frequency or digital (S3L) sensor output can be used with Georg Fischer's extensive line of flow instruments while the 4 to 20 mA output can be used for direct input to PLCs, chart recorders, etc. Both the 4 to 20 mA output and the digital (S3L) sensor interface are available for long-distance signal transmission. An additional benefit is the empty pipe detection which features a zero flow output when the sensors are not completely wetted. Also, the frequency output is bi-directional and can be set using the 4 to 20 mA output, using the display, or the 3-0250 USB to Digital (S3L) set-up tool. The display version is available with relays and features permanent and re-settable total values which can be seen on the display. The display contains multi-language options such as English, Spanish, German, French, Italian and Portuguese.

    Magmeter Flow Sensor - Features

    • Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in
    • Operating range: 0.05 to 10 m/s, 0.15 to 33 ft/s
    • Max Pressure rating: PP 10.3 bar @ 25 °C, 150 psi @ 77 °F
    • Power source: 4 to 20mA: 21.6 to 26.4 VDC, 22.1mA max
    • Empty pipe detection
    • Frequency output bi-directional
    • Material options: PP with stainless steel, PVDF with stainless steel, PVDF with Hastelloy-C, or PVDF with Titanium
  • pH/ORP Wet-Tap Electrodes | Signet 2756-2757

    pH/ORP Wet-Tap Electrodes  - Overview

    The Wet-Tap pH and ORP electrodes are sensors which are ideal for a wide range of applications where the installation and removal of the electrode can be performed without the need for system shutdown. The Signet 3719 pH/ORP Wet-Tap Assembly allows the installation and removal of pH or ORP electrodes under process pressure, without process shutdown during routine maintenance and calibration. Process isolation is achieved during electrode retraction with two sets of double O-ring seals on a unique and compact retraction assembly; no separate valve is required. The DryLoc connector with corrosion-resistant gold-plated contacts readily connects the sensor to the mating 2751 pH/ORP Smart Sensor Electronics or the 2760 Preamplifier. The robust polyarylsulphone (PAS) body and choice of bulb pH or flat ORP sensing elements allow a broad range of chemical compatibility for a wide range of applications. The quick temperature response is available in either a Pt1000 or 3 KΩ temperature sensor and allows compatibility with all Signet pH/ORP instruments.

    pH/ORP Wet-Tap Electrodes  - Features

    • Installation at any angle - inverted or horizontal
    • PTFE reference junction resists fouling and chemical attack
    • Polyarylsulphone (PAS) body for broad range of chemical compatibility
    • General-purpose bulb pH glass suitable for a wide range of applications
    • Patented DryLoc connector with gold-plated contacts
    • Pt1000 or 3 KOhm Balco temperature element for quick temperature response
    • Electrode removal without process shutdown (when part of Signet 3719 pH/ORP Wet-Tap Assembly)
    • Memory chip-enabled for access to features when connected to the Signet 2751 pH/ORP Smart Sensor
  • Water Jet Suction Pump Valve | GF P20

    Water Jet Suction Pump Valve - Overview

    The water jet suction pump valve can be used where the liquid is under pressure and is present as a propellant. It is used for transporting and mixing liquids. The water jet suction pump valve is self-priming and has no mechanically moving parts. The basic principle of the water jet suction pump is that the propellant liquid passes through a nozzle and draws in with it the liquid or gaseous medium from the suction line, increasing its velocity. The result is that the propellant and the medium are sucked in and mixed together. Suitable for use in aquariums, the chemical process industry, industrial water treatment, and swimming pools.

    Water Jet Suction Pump Valve - Features

    • No external energy required for operation
    • Ideal for mixing, dosing and transporting liquids
    • No mechanically moving parts
    • Self-priming
  • Free Chlorine Sensor | Chlori::lyser

    Free Chlorine Sensor - Overview

    The chlori::lyser is a revolutionary sensor for monitoring free chlorine or total chlorine. Its internal buffer electrolyte allows pH-independent measurement between pH 4 to 9+, and its 3-electrode system provides extremely stable readings. These sensors were developed for use in drinking water, pool water and different types of water treatment. The usage in wastewater is possible but has to be evaluated for the specific application. These sensors have only a low dependence on fluctuations of flow. However, a constant flow of the measuring medium is recommended. High precision is ensured even at high fluctuations of pH, temperature and flow. chlori::lyser™ monitors free chlorine (Cl2 + HOCl + OCl-) or total chlorine (free chlorine + combined chlorine)

    Free Chlorine Sensor - Features

    • s::can plug & measure
    • measuring principle: amperometric (membrane covered)
    • ideal for drinking water
    • long-term stability
    • low maintenance
    • replacement of membrane only once a year
    • readings stable at high fluctuations of pH, temperature and flow
    • compensates fluctuations of pH in an unmatched way
    • pH range from 4 to 9 FCl
    • pH range from 4 to 12 TCl
    • cross sensitivities to chlorine dioxide, ozone can be compensated by using readings from spectro::lyser™
    • factory zero point pre-calibrated
    • mounting and measurement in flow cell
    • operation via s::can terminals & s::can software