Tag: Pure Water Treatment

Pure Water Treatment

  • Online water monitoring

    Drinking Water Monitoring Station | Micro Station

    Call for price

    Overview of Drinking Water Quality Monitoring | Micro-Station.

    Modular online monitoring station combines s::can instruments in a compact and versatile system for easy plug and play installation. The user only has to connect water supply and -discharge (“plug & measure”) in order to receive a previously unheard of parameters immediately. The s::can micro::station is designed for Online monitoring of water quality parameters, in particular a focus on Turbidity and Total Organic Carbons, Dissolved Organic Carbons in clean media, such as drinking water. The components depending on the station model could include a - spectro::lyser, s::can probes and controller  all factory assembled with required flow cells, mounting fittings and pipework on a compact panel. The micro::station is a s::can solution for water analysis- compact and easy like never before.

    Can be used for process control with many applications utilizing a forward feed process control "predictive dosing"

    Micro-station Water Quality Monitoring Features:

    • Plug and play setup.
    • No Reagents  or titration system
    • Minimal maintenance.
    • Event Detection
      • Event detection module
      • Online Validation
      • Spectral Alarm
    • Online Measurement of multiple Parameters
      • NTU/FTU - Turbidity
      • Color
      • UV254
      • TOC - Total Organic Carbons
      • DOC - Dissolved Organic Carbons
      • NO3
      • NO2
      • Temperature
      • NH4
      • pH
      • K
      • Conductivity
      • Free or Total Chlorine
      • H2O2
      • CLO2
      • PAA
  • GF electronics Junction box Conductivity/Resistivity 2850

    Resistivity, Conductivity Electronics – 2850

    Call for price

    Resistivity or Conductivity Electronics Overview

    The GF Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The threaded j-box version can be used with these same GF Signet sensors for submersible sensor mounting.  Universal mount version used for pipe, wall, or tank mounting and enables single or dual (digital output only) inputs using any standard GF Signet conductivity / resistivity sensor. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, 10.0, or 20.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 400,000 µS or a resistivity range of 100 MΩ to 10 kΩ. Each range can be inverted and are field selectable.

    All 2850 units are available with a choice of a single or dual digital (S3L) outputs, or a single 4 to 20 mA. The single digital (S3L) output version can be paired with the 9900 Transmitter to extend the distance between the measuring points to 120 m (400 ft).

    The 8900 Multi-Parameter Controller allows for up to six sensor inputs directly into the Georg Fischer  Signet  8900 Multi-Parameter Controller. All 2850 units are built with NEMA 4X/IP65 enclosures which allow output wiring connections with long cable runs of up to 305 m (1,000 ft).

    Resistivity or Conductivity Electronics Features

    • Accepts any cell constant
    • Compatible with all GF Signet  Conductivity Sensors
    • Output choices include digital (S3L) for use with the 4 to 20mA of GF Signet 8900, 9900, 9950
    • Compatible with GF Signet  Instrument Type 8900 or instruments accepting a 4 to 20mA output
    • Single or dual input available for remote mount version (S3L) only
  • Spectrometer vertical profile 100 path length spectro::lyser

    UV-VIS Spectrometer V2, spectro::lyser | s::can

    Call for price

    UV-Vis Spectrometer Overview

    The spectro::lyser™ measures the entire absorption spectrum and is used by many drinking water providers all over the world as a pivotal component in their raw water monitoring. The spectro::lyser™ with its capability to measure and analyze the absorption spectrum in its entirety with 256 different wave lengths allows detection of a multitude of organic substances.

    spectro::lyser™ UV monitors depending on the application an individual selection of: NO3-N, COD, BOD, TOC, DOC, UV254, NO2-N, BTX, AOC, fingerprints and spectral alarms, temperature and pressure.

    spectro::lyser™ UV-Vis monitors depending on the application an individual selection of TSS, turbidity, NO3-N, COD, BOD, TOC, DOC, UV254, color, BTX, O3, H2S, AOC, fingerprints and spectral-alarms, temperature and pressure.

    UVVIS Spectrometer Features

    • s::can plug & measure
    • measuring principle: UV-Vis spectrometry over the total range (200-750 nm or 200-390 nm)
    • optical path lengths available to increase accuracy 100mm, 35mm, 5 mm, 2 mm, 1 mm or 0.5 mm possible
    • multi parameter probe with adjustable open path length
    • ideal for surface water, ground water, drinking water and waste water
    • long term stable and maintenance free in operation
    • factory pre-calibrated, local multi-point calibration possible
    • automatic cleaning with compressed air or brush/ruck::sack
    • mounting and measurement directly in the media (InSitu) or in flow cell (monitoring station)
    • operation via s::can terminals & s::can software
    • recommended by and compliant with public authorities and international agencies such as Chinese EPA, US EPA and CPCB
  • Water Quality on your phone with nano::station

    Water Quality Monitoring | Nano Station

    Call for price

    Overview of Drinking Water Quality Monitoring | Nano-Station.

    Modular online monitoring station combines s::can instruments in a compact and versatile system, for easy plug and play installation. The user only has to connect water supply and -discharge (“plug & measure”) in order to receive a previously unheard of parameters immediately. The s::can nano::station is designed for Online monitoring of water quality parameters, in particular a focus on Turbidity and Total Organic Carbons, Dissolved Organic Carbons in clean media, such as drinking water. The components depending on the station model could include a - i-scan, s::can probes and controller  all factory assembled with required flow cells, mounting fittings and pipework on a compact panel. The micro::station is a s::can solution for water analysis- compact and easy like never before.

    Can be used for process control with many applications utilizing a forward feed process control "predictive dosing"

    Nano Station Water Quality Monitoring Features:

    • Plug and play setup.
    • No Reagents or titration system
    • Minimal maintenance.
    • Event Detection (possible with concube)
      • Event detection module
      • Online Validation
      • Spectral Alarm
    • Online Measurement of multiple Parameters
      • NTU/FTU - Turbidity
      • Color
      • UV254
      • TOC - Total Organic Carbon
      • DOC -Dissolved Organic Carbons
      • Temperature
      • pH
      • Conductivity
      • Free or Total Chlorine
      • H2O2
      • CLO2
      • PAA