Tag: Sanitization Systems

Sanitization Systems

  • pH and ORP Electrodes | 2724, 2726, 2725

    Price range: R8,121.00 through R18,103.00

    pH and ORP Electrodes - Overview

    The Georg Fischer 2724-2726 pH and ORP Electrodes feature a patented reference electrode design and use the unique foul-proof DryLoc® connector. The large area PE reference junction and pathway are constructed to increase the total reference effectiveness and ensure long service life.

    The DryLoc connector with corrosion-resistant gold-plated contacts readily connects the sensor to the mating 2760 preamplifier or the 2750 sensor electronics. The robust Ryton® threaded sensor body and choice of flat pH, bulb pH, or flat ORP sensing elements provide a broad range of chemical compatibility for a wide variety of applications.

    There are two optional sensing versions, HF and LC, available. The quick temperature response is available in either a PT1000 or 3 KΩ temperature sensor and allows compatibility with all Georg Fischer pH/ORP instruments. The 2724-2726 electrodes are general-purpose sensors ideal for a wide range of applications. The sensors incorporate ¾” NPT or ISO 7-1 R¾ thread for installation into standard pipe tees. They can also be mounted directly into Georg Fischer's standard fittings.

    pH and ORP Electrodes - Features

    • Wetted Materials: Ryton, UHMW polyethylene, FKM, glass
    • Connection: Durable DryLoc® with gold-plated connections
    • Compatible Preamp/Sensor Electronics: 2750 and 2760
    • Compatible Instruments: Use the 2760 preamplifier with the Georg Fischer 8750; Use the 2750 sensor electronics with the Georg Fischer 8900, 9900 or 9950 instruments
    • Additional Features: HF and LC options available
    • In-line Mounting styles:  Standard 3/4 inch or ISO threaded fittings
    • Submersible mounting: Available using the back of the preamplifier or sensor electronics
  • pH/ORP Smart Sensor | 2751

    pH/ORP Smart Sensor - Overview

    This smart sensor is a solution for field-free calibration, out-of-range glass impedance, and broken glass detection, alerting the operator to probe failure or maintenance needs. It features two different outputs: a two-wire 4 to 20 mA loop output with optional EasyCal function or a digital (S3L) output that allows for longer cable lengths. The pH/ORP Electronics will allow for calibration of electrodes in a laboratory setting and installation of pre-calibrated probes in the field, reducing system downtime. Memory chip-enabled electrodes will store operational data such as minimum and maximum pH/mV readings, runtime, and minimum and maximum temperature (pH only), for troubleshooting and operational evaluation. The 2751 self-configures for pH or ORP operation via automatic recognition of the electrode type. The optional EasyCal feature allows simple push-button calibration and includes an LED  indicator for visual feedback.

    pH/ORP Smart Sensor - Features

    • Probe health monitoring, glass impedance, and broken glass detection
    • Memory chip interface that allows for transferable calibration, runtime data, and manufacturing information
    • In-line integral mount and submersible installation versions
    • Automatic temperature compensation
    • Auto-configuration for pH or ORP operation
    • Optional EasyCal calibration aid with automatic pH buffer recognition for 4, 7, and 10 pH and ORP  solutions: quinhydrone saturated pH 4 or 7 buffers and Light's Solution +469 mV
    • Junction boxes for convenient wiring
    • Patented DryLoc® connector provides a quick and secure connection to the sensor

    Datasheet