Portable Ultrasonic Flowmeter | GF PF220/330 V2

Portable Ultrasonic Flowmeter | GF PF220/330 V2

Portable Ultrasonic Flowmeter – Overview

The Ultrasonic Portaflow range brings simplicity to non-invasive measurement of liquid flow. The ‘Clamp-On’ concept makes the installation of the sensors in running systems possible as the pipe does not have to be opened.  It offers quick and accurate flow measurements. It has an easy-to-follow menu and a simple setup. They are compact, rugged and reliable. The Portaflow range is designed to provide sustained performance in industrial environments. Suitable for temporary or semi-stationary use. The Portable Ultrasonic Flowmeters are compatible with almost all pipe types including PVDF-ABS, PVC, PP, PE, PB-Instaflex, iron and steel pipes. Measurements can be viewed directly on-site with the large graphic display or logged and exported to a PC for further analysis (PF330 V2 (HM) versions). One 4-20 mA output and three individually configurable pulse outputs enable easy integration into higher-level systems. Also available is the GF PF330 V2 Heat Meter (HM) which is equipped with Pt100 temperature sensors to calculate the energy of a heat exchanging system enabling it to work as a heat meter/energy meter/BTU meter.

Portable Ultrasonic Flowmeter – Features

  • Large, easy-to-read graphic display with backlighting
  • Easy to install
  • ‘Clamp-On’ design
  • Datalogger option (up to 100 million data points PF330)
  • USB port for easy data export (PF330)
  • Analogue, pulse & alarm outputs
  • Battery lifetime up to 14 hours
  • Compatible with almost all pipe types
  • Automatic energy calculation with two Pt100 temperature sensors (HM version)

Description

Portable Ultrasonic Flowmeter | GF PF220/330 V2

Specifications
General
Measuring Method Ultrasonic transit-time measurement
Flow Range 0.1 m/s to 20 m/s
Accuracy Pipe ID >75 mm: ±0.5% to ±2% of flow reading for flow rate >0.2 m/s
Pipe ID 13 mm – 75 mm: ±3% of flow reading for flow rate >0.2 m/s
All pipe ID’s: ±6% of flow reading for flow rate <0.2 m/s
Repeatability ±0.5% of measured value or ±0.02 m/s whichever is the greater
Response Time < 500 ms depending on pipe diameter
Selectable Flow Units Velocity: m/sec, ft/sec.
Volume: “l/s, l/min, l/h, gal/min, gal/h, USgals/min, USgals/h, Barrel/h, Barrel/day, m³/s, m³/min, m³/h”
Selectable Total Volume Units liter, gallons, US gallons, Barrel, m³
Total Volume 12 digits
Menu Languages EN, DE, FR, RU, SWE, IT, SP, P, NO, DEN (user selectable)
Temperature sensors (Heatmeter models only)
Operating Temperature 0 °C to 50 °C
Storage Temperature -10 °C to +60 °C
Temperature of Pipe Wall -20 °C to +85 °C
Accuracy Pt100 Class B 4-wire
Resolution 0.1 °C
Humidity During Operation ax. 90% relative humidity at +50 °C
Environmental
Operating Temperature -20 °C to +50 °C
Storage Temperature -25 °C to +65 °C
Pipe Wall Temperature -20 °C to +135 °C
Operating Humidity Max. 90% relative humidity @ +50°C
Suitable Pipe Types
Pipe Materials PVDF, PP-H, PE, PB, ABS, UPVC, CPVC, construction steel, iron, stainless steel, copper
Pipe Diameter (OD) 13 mm to 2000 mm
Pipe Wall Thickness 1 mm to 75 mm
Pipe Lining Applicable pipe linings include Rubber, Glass, Concrete, Epoxy, Steel
Pipe Lining Thickness 0 mm to 10 mm
Electronics
Power Supply 9 to 24 V DC
Power Consumption Max. 10.5 W
Battery
Technology 5-cell NiMH
Capacity 3.8 Ah
Operating Time (typical) Typically 20 hours continuous with backlight and 4 to 20 mA output OFF
Recharge Time 6.5 h
Service Life >500 charge/discharge cycles
AC Adapter
Input Voltage 90 to 264 V AC (47 to 63 Hz)
Output Voltage 12 V DC
Output Current Maximum 1.5 A
Approvals UL, CUL, TUV, CB, CE
Outputs
Analog Output Range: 4 to 20 mA, 0 to 20 mA, 0 to 16 mA
Resolution: 0.1% of full scale
Load Max.: 620 Ω
Isolation: 1500 V Opto-isolated
Alarm Current: Adjustable between 0 to 26mA
Pulse Output Type: 3x Opto-isolated MOSFET volt free contact (NO/NC)
Options: Flow totals, energy (HM version only), loss of signal, low flow alarms.
Pulse sequence: Volumetric mode: 1 to 50 pulses/sec user-programmable
Frequency mode: 200Hz max. pulse frequency
Pulse Width: 50 ms standard value, 3 to 99 ms user-programmable
Max. Voltage: 48 V
Max. Current: 150 mA
Isolation: >110 V AC/DC
USB Interface (PF330 V2 only) Protocol: Supports full speed (12Mbits/sec) data connection
Software: USB driver software is provided with the package
Connector: USB Typ-A female
Data Logger (PF330 V2 (HM) only)
Data Logged
application details, time, date, flowrate, forward total, reverse total, flow velocity, flow side temperature, return side temperature, temperature difference, power, total energy, signal quality, signal SNR, signal status
Number of Data Points 100 million
Number of Data Sites 12
Number of Data Points per Site No limit
Programmable Logging Interval 5 s to 1 h
Start / Stop Manually or timer controlled
Data Download USB interface
Transducer Sets
Type A 13 to 114 mm (½ inch to 4.5 inch) pipe OD (2MHz)
Type B 50 to 2000 mm (2 inch to 40 inch) pipe OD (1MHz)
Housing and Display
Material ABS
Dimensions 264 x 168 x 50 mm
Weight 1.1 kg (incl. battery)
Keypad 16 key tactile feedback membrane keypad
Display Type: 240 x 64 pixel graphic display, high contrast black-on-white, with backlight
Viewing angle: Min. 30°, typically 40°
Active area: 127 x 34 mm 5
Protection class IP 54
Shipping Information
PF330 Packaging Dimensions: 420 x 390 x 220 mm
Weight: 7.5 kg
Volume Weight: 5.7 kg
PF220 Packaging Dimensions: 510 x 140 x 440 mm
Weight: 6 kg
Volume Weight: 5.2 kg
Standards and Approvals
CE, RoHS compliant
Safety BS EN 61010-1:2010
EMC BS EN 61326-1:2013
BS EN 61326-2-3:2013
Power Supply EN61204-3
UL, CUL, TUV, CB, CE
Environmental BS EN 60068-1:2014
BS EN 60068-2-1:2007

Portable Ultrasonic Flowmeter | GF PF220/330 V2

Brand

Georg Fischer

georg Fischer Signet logo

Reviews

There are no reviews yet.

Be the first to review “Portable Ultrasonic Flowmeter | GF PF220/330 V2”