Royce Water Product Categories

Royce Water Product Categories

  • Online PH Sensor | LH-DPH07

    Online PH Sensor - Overview

    This digital sensor is suitable for real-time pH value monitoring in industrial wastewater, water works, food processing, pharmaceutical, and other industries. It integrates electronic circuits and microprocessors inside the sensor.

    Online PH Sensor - Features

    • ≤±0.02pH Accuracy
    • 0~60C Working Temperature
    • 20 s Response Time
    • Measuring range 0.00-14.00pH
    • IP68
  • Online Conductivity Sensor | LH-DE26

    Online Conductivity Sensor  - Overview

    The two-electrode online conductivity sensor uses graphite which has good test accuracy and stability. It uses RS485 communication interface, supports MODBUS protocol, and has a built-in high-precision NTC sensor to perform accurate temperature compensation for conductivity measurement in real time.

    Online Conductivity Sensor  - Features

    • Graphite electrode has higher measuring range, stability and accuracy
    • Excellent performance
    • Measuring range 0-20mS/cm, indication error ±1%
    • Digital electrode, MODBUS protocol, supports RS485 output
    • Using 1% high-precision NTC temperature sensor
    • 316 stainless steel shell material
  • Online Turbidity Sensor | LH-DZ09-200

    Online Turbidity Sensor  - Overview

    The online turbidity electrode is widely used in drinking water treatment plants, sewage treatment plants, integrated purification tanks, the paper industry, and chemical industries. The online turbidity electrode adopts a 90-degree scattered light method and uses a near-infrared light source to eliminate chromaticity interference. It meets the IS07027 standard. The beam will emit scattered light when it hits the suspended matter in the sample during transmission. The detector set at 90% of the incident light receives the scattered light, which is directly proportional to the concentration of suspended matter in the sample. Turbidity can be calculated by measuring the intensity of the scattered light.

    Online Turbidity Sensor  - Features

    • Automatic, smart cleaning function
    • Sensitive response
    • Wide detection range
    • Can be used for low turbidity detection (<1NTU, with flow slot)
    • Multiple output methods
    • Support MODBUS / RS485 4-20mA current interface output
    • Built-in temperature sensor with temperature compensation function
  • Resistivity, Conductivity Electronics | 2850

    Price range: R14,489.00 through R20,265.00

    Resistivity or Conductivity Electronics Overview

    The GF Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility. The threaded j-box version can be used with these same GF Signet sensors for submersible sensor mounting.  Universal mount version used for pipe, wall, or tank mounting and enables single or dual (digital output only) inputs using any standard GF Signet conductivity / resistivity sensor. It is also available as a combined integral system configuration for in-line mounting and includes a conductivity electrode in a choice of 0.01, 0.1, 1.0, 10.0, or 20.0 cm-1 cell constants. The 2850 is ideal for applications with a conductivity range of 0.055 to 400,000 µS or a resistivity range of 100 MΩ to 10 kΩ. Each range can be inverted and are field selectable.

    All 2850 units are available with a choice of a single or dual digital (S3L) outputs, or a single 4 to 20 mA. The single digital (S3L) output version can be paired with the 9900 Transmitter to extend the distance between the measuring points to 120 m (400 ft).

    The 8900 Multi-Parameter Controller allows for up to six sensor inputs directly into the Georg Fischer  Signet  8900 Multi-Parameter Controller. All 2850 units are built with NEMA 4X/IP65 enclosures which allow output wiring connections with long cable runs of up to 305 m (1,000 ft).

    Resistivity or Conductivity Electronics Features

    • Accepts any cell constant
    • Compatible with all GF Signet  Conductivity Sensors
    • Output choices include digital (S3L) for use with the 4 to 20mA of GF Signet 8900, 9900, 9950
    • Compatible with GF Signet  Instrument Type 8900 or instruments accepting a 4 to 20mA output
    • Single or dual input available for remote mount version (S3L) only
  • Conductivy Sensor | Condu::lyser

    Price range: R37,538.00 through R42,298.00

    Overview of Conductivity Sensor Condu-lyser

    The condu::lyser is a maintenance-free and long-term stable probe for online measurement of conductivity, automatically compensated with temperature. It can be mounted directly in the media or in a flow cell providing high precision by either conductive or inductive measurement. Thanks to the 4 electrode high measurement range it is ideal for all varieties of water. One sensor for all applications. 2 versions available one sensor with plug connector for use in monitoring or bypass stations, sensor with fixed cable for submersion directly into media.

    Conductivity sensor Features:
    • s::can plug & measure
    • measurement principle condu::lyser: 4 electrode contacting measurement
    • multi parameter sensor(temp and EC)
    • ideal for surface water, ground water, drinking water and waste water
    • steam sterilizable, autoclavable and compatible with Cleaning In Place (CIP)
    • condu::lyser monitors conductivity, temperature and salinity
    • long term stable and maintenance free in operation
    • high temperature, pressure and measuring range
    • factory pre-calibrated
    • mounting and measurement directly in the media (InSitu) or in a flow cell
    • operation via s::can terminals & s::can software
    • optional: automatic cleaning with compressed air
  • Fine Control Valve | FCV

    Fine Control Valve  - Overview

    This valve comes in a selection of fine-control needles suitable for the gradual opening and closing of gas or liquid flows. Suitable for use with all Platon glass Tube VA flowmeters, the standard FCV is rated at up to 25 bar line pressure. As with all control valves, the FCV is not designed for a total leak-free shut-off.

    Fine Control Valve  - Features

    • Liquids or gases
    • Brass or Stainless Steel Options
    • 1/4" BSPP Connection fits directly into pipework
    • Fits in any orientation
    • Choice of low, medium or high flow control
    • Ideal for use with NGXI, LGXI and GU flowmeters
  • Multifunctional Pen-Type TDS Tester | LH-TDS9

    R337.00

    Multifunctional Pen-Type TDS Tester - Overview

    This multifunctional water quality detection pen detects the TDS value (total dissolved solids, unit is ppm) and conductivity value (the conductivity of the solution, unit is us/cm) of water. It has a measuring range of 0~9999ppm,0-9999us/cm. It measures the purity of the water, as well as the water temperature and the environmental temperature. It is suitable for use in the water treatment industry, residences and outdoors.

    Multifunctional Pen-Type TDS Tester - Features

    • Light and handy
    • Wide measurement range
    • Long battery life
    • Easy to clean
    • Quick measurement
    • Large LCD screen
  • Online Multiparameter Universal Controller | LH-D6901

    Online Multiparameter Universal Controller  - Overview

    This intelligent online controller is widely used in water quality detection and monitoring in sewage plants, waterworks, water stations, surface water and other industries.  Its modular design offers various modules of more than 20 kinds of sensors, which can be combined at will, as well as reserved expansion functions. It can measure 4 parameters similtaneously and has 2 analogue outputs.

    Online Multiparameter Universal Controller  - Features

    • High definition color touch screen
    • Strong expansibility and practicability
    • Multiple output modes
    • IP65 waterproof
    • High and low alarm
    • Chinese and English interface
    • Remote communication
    • History record
    • Customisation services
  • Turbidity or TSS UVlyser | uv::lyser V3

    Turbidity or TSS UVlyser - Overview

    The UVlyser monitors Turbidity or TSS and up to 4 freely chosen wavelengths between 190 and 720 nm. The UVlyser provides cost-effective and accurate solutions for surface water, drinking water, groundwater, and wastewater applications.

    Turbidity or TSS UVlyser - Features

    • UV-Vis spectrometry over the total range (190-750 nm)
    • web server onboard – IoT enabled 
    • communicates directly with your mobile device via WLAN
    • choose exactly the parameters you want to measure  
    • 8 GB onboard memory  
    • improved optical performance
    • revolutionary precision
    • fast measurement interval – every 10 seconds
    • extremely power efficient 
    • multiparameter probe with 1 mm, 5 mm, or 35 mm optical path length,
    • ideal for wastewater, surface water, and drinking water
    • long term stability
    • virtually maintenance-free in operation
    • factory pre-calibrated, local multi-point calibration possible
    • automatic cleaning with compressed air or brush/ruck::sack

     

  • Galvanic DO Analyser | 2100

    Galvanic DO Analyser - Overview

    This Dissolved Oxygen (DO) Monitoring and Control System is a rugged dissolved oxygen analyser which utilises a long-life, low-maintenance galvanic DO sensor. It provides the user with exactly what they need for continuous DO monitoring and control of important aeration processes. It seldom requires maintenance or recalibration. It has a backlit display and comes with a digital output,  two analogue outputs, and two control relays.  It is a fully-powered, continuous monitoring and control analyser. It is used in combination with a galvanic DO sensor.  The galvanic sensor has a pure platinum cathode, making the sensor incapable of being poisoned by other gases often found in impure waters, such as hydrogen sulfide. It utilises DO sensing technology that is successful in continuous de-nitrification monitoring and control applications. It can be used continuously in very violent pure liquid oxygen injection systems. Complete systems are supplied with over 5 years of sensor electrolyte and membranes. When used correctly, these Teflon® membranes will last well over a year and require minimal maintenance.

    Galvanic DO Analyser  - Features

    • Analyser and sensor
    • Low maintenance
    • Harsh environments
    • Versatile applications
  • Portable Turbidity Analyser | PMI800

    Portable Turbidity Analyser - Overview

    The Portable Water Analyser is paired with the Turbidity Sensor, enabling convenient, accurate, and easy measurement of turbidity.  It is comfortable to operate because of its ergonomic design and is available with single or dual-channel configurations.

    Portable Turbidity Analyser  - Features

    • IP67 protection rating
    • 3.5-inch color screen display
    • Easy to use interface and menu
    • Ergonomic design for holding
    • Non-slip hand strap
    • Data storage space 8G
    • Data export via USB interface
    • Built-in rechargeable battery
    • Charging directly via USB
    • Automatically identifies sensor type and automatically adapts
    • Parameter can be set and calibrated on sensors

     

  • Liquid Low Flow Alarm | Platon DS1431

    Liquid Low Flow Alarm - Overview

    Suitable for liquid low-flow or flow-failure alarm on cooling systems, water heaters or lubrication systems. This rugged sensor has a simple electrical reed switch output. Installed in a vertical line with flow upwards, the normal flow lifts the float in the sensor. A magnet encapsulated in the float then actuates a reed switch, giving contact closure. Should the flow drop to below the preset alarm level, the float falls to the rest position and the contacts open to give an alarm output. Available in 1/2” and 3/4” line sizes, with BSP female threaded connections. Alarm rates are factory set between 0.5 L/min and 10 L/min to suit most applications. The standard unit is brass and has a one-piece body suitable for high pressures, with no glands or seals to leak. The externally mounted reed switch has flying leads for local connection to a terminal block. Typical applications include water supply flow failure into heaters or boilers (where the flame or power supply is cut to prevent overheating accidents), for lubricant or cutting fluid flow failure in machine tools or gearboxes. For flow failure alarm in cooling circuits, the LF flowswitch is used on X-ray equipment, electron microscopes, transformers, radio transmitters and high frequency generators.

    Liquid Low Flow Alarm - Features

    • Low-cost flow alarm
    • Simple rugged construction
    • Brass, BSP connections
    • Selectable alarm trip level (factory set)
    • No glands or seals
    • Stainless Steel and other special OEM versions available
  • Non-contact Radar Level Transmitter | GF 2298

    Non-contact Radar Level Transmitter  - Overview

    This rugged, high-performance radar level measurement sensor has a transducer and processing electronics incorporated in one. It is suitable for single and multiple-tank applications. 2-wire sensors are recommended using either HART protocol or 4 to 20 mA for direct communication with a panel mount controller or a PLC. This is used for liquid level measurement in sumps or tanks, for tank volume measurement, or open channel flow measurement. Sensing ranges up to 20 m (66 ft) are available. PP and PVDF sensor bodies provide the best chemical resistance in applications where concentrated chemicals need to be detected. Applications include Water Treatment, Corrosive Industrial Waste Treatment, Filling, Batching, Bulk Transfer, and Dirty Liquids.

    Non-contact Radar Level Transmitter  - Features

    • 2-wire compact sensor
    • Compatible with 9900 Sensor (optional signal converter)
    • Non-contact level measuring
    • Narrow 7° beam angle
    • Level, volume and open channel flow
    • Compact housing
    • Fully temperature-compensated electronics
    • Outstanding signal processing software providing highly accurate measuring results
    • Chemical resistance - PP or PVDF sensor body
    • Secondary lightning protection
    • 4 to 20 mA / HART interface
  • Non-contact Radar Level Transmitters | PiloTREK WP–200

    Non-contact Radar Level Transmitters - Overview

    This non-contact radar level transmitter uses 80 GHz FMCW radar. The key advantages of 80 GHz technology are a smaller antenna size, improved focusing capability, and a narrower beam angle. This can be used to measure liquids, bulk solids, emulsions, and chemicals across the water, food, energy, pharmaceutical, and chemical industries, delivering millimetre-accurate results. This is also well suited for liquids with a gas blanket, vapour-prone substances, and large-particle bulk solids. This includes open-channel flow measurement and has threshold functions to suppress false and interfering echoes. The transmitter can also operate in a vacuum. The device can also be used with HART® compliant NIVELCO EView2, MultiCONT universal process controller, MonoCONT smart field display & data logger, and PACTware™ software, or configured via Bluetooth® communication using the MobileEView application.

    Non-contact Radar Level Transmitters - Features

    • Measuring range up to 30 m
    • Configuration via Bluetooth® with MobileEView app
    • PACTware™ compatible
    • 5 years warranty
    • Ex variant
    • 2-wire 80 GHz (W-band) radar
    • Accuracy of ±2 mm
    • Easy to install
    • 1", 1½" encapsulated antenna
    • Submersible
    • User-friendly threshold management

    [embed]https://www.youtube.com/watch?v=DZEVUFEXHR4[/embed]

  • Online Biological Oxygen Demand Analyser | BIO Series

    Online Biological Oxygen Demand Analyser - Overview

    These bio-electrode sensors (BES) allow you to reliably measure and monitor the changing BOD or VFA concentrations in wastewater. IT has a sensor biofilm which is customised to the following applications: wastewater collection networks, influent locations of wastewater treatment facilities,  anaerobic selectors for biological nutrient removal, and anaerobic digestion environments.  The sensors monitor biological oxidation of organic carbon in wastewater streams by measuring the rate at which in-situ and customised biofilm surfaces consume the available food.  A biofilm is established on the sensor after 1-3 days in the wastewater stream. This bio-electric surface then uses the sensor current collector to generate a flow of electrons that is equivalent to the rate of organic carbon oxidation. This flow of electrons is measured and displayed on an online dashboard and updated every minute. Increasing BOD in wastewater will result in increased metabolic activity and sensor signal; acute chemical toxicity or significant dilution of BOD will result in low alert signals and reduce metabolic activity. This results in reliable, real-time insight into biological treatment rates and performance. These microbial, fuel cell-based sensors are robust and are used in the most challenging situations. Very little maintenance or cleaning is required. It highlights microbial activity variations, organic matter degradation, and process upsets, which can guide your operations.

    Online Biological Oxygen Demand Analyser - Features

    • Real-time monitoring of consumable BOD/VFA or rbCOD surrogate
    • Plug-and-play functionality
    • Multiple connectivity options (analogue, Ethernet, Wi-Fi)
    • Smart Sampling Program reduces labour and analysis costs
    • Low maintenance