Process Optical Dissolved Oxygen Sensor – Overview

This rugged, reliable sensor is designed to deliver accurate dissolved oxygen (DO) data across a wide measuring range.  It features the latest optical technology for DO measurement and eliminates the replacement of membranes and reference solutions. The optical sensor cap is calibrated at the factory and requires no field calibration. The optical measurement technology resists abrasion and bleaching which allows for a long life in many harsh applications. It has built-in Modbus RS485 and 4 to 20 mA current loop outputs for ease of interface to existing control systems. The 3-2610-51 version includes the GF (S3L) digital interface for direct connection with the 9900 SmartPro® Transmitter and 9950 SmartPro® Dual Channel Transmitter. Additional features include a 10 m (32.8 ft) cable with stripped and tinned ends as well as a titanium temperature sensor for improved compatibility in saltwater applications.

Process Optical Dissolved Oxygen Sensor  – Features

  • Two-year measurement cap life
  • Optical DO measurement – no minimum flow requirements
  • Rugged construction
  • Suitable for harsh conditions
  • Measurement range: to 60 mg/L (ppm)
  • Calibration built into the measurement cap
  • Accuracy ±0.1 mg/L, 0 to 20 mg/L; ±5% of reading, 20 to 60 mg/L
  • No membranes or filling solutions
  • Digital (S3L), 4 to 20 mA or Modbus
  • In-line or submersible

Description

Process Optical Dissolved Oxygen Sensor | 2610

General
Sensor type Optical luminescent dissolved oxygen sensor
Transmitter/Local Display
Optional, not required. Compatible with SmartPro instruments
Communications Options Digital (S3L), 4-20 mA, Modbus (RS485)
Maximum Cable Length Modbus and 4 to 20 mA: up to 1’219 m (4’000 ft)
Digital (S3L): 38 m (125 ft)
Internal Mounting Thread 1¼ NPT
Power Requirements
12 to 24 VDC ±10% regulated (Note: external power supply, cannot be powered by GF transmitters directly)
4 to 20 mA output span
0 to 20 mg/L and 0 to 60 mg/L are factory defaults, either unit can be respanned anywhere in between (contact GF Sales office)
Performance
Salinity Range 0 to 42 PSU, fixed or real-time capable
pH Range 2 to 10 pH
Barometric Range 507 to 1115 mbar, fixed or real-time capable
Maximum Pressure 150 psi @25°C
Range 0 to 60 mg/L concentration
Units mg/L, ppm, %SAT
Accuracy (DO) ±0.1 mg/L, 0 to 20 mg/L,
±5% of reading, 20 to 60 mg/L
Response Time of Cap T90: 30 sec
T95: 37 sec @ 25 °C
Repeatability 0.05 mg/L
Resolution 0.01 mg/L
Environmental
Wetted Materials ABS, Titanium and FKM
Usage Life of Cap 2 years from the first instrument reading
Shelf Life of Cap
24 months from date of manufacture (install within 12 mo. of manufacture)
Operating Temperature 0 °C to 50 °C
IP Rating IP-67 with cap off, IP-68 with cap installed
Compliance Heavy industrial, IEC 61000-6-2:2005
Storage Conditions, Cap 1 °C to 60 °C
Storage Conditions, Sensor -5 °C to 60 °C
Warranty
Sensor 3 years from date of manufacture
Standards and Approvals
CE, FCC
RoHS Compliant, China RoHS