Precession Vortex Flowmeter | LUGB

Precession Vortex Flowmeter | LUGB

Precession Vortex Flowmeter  – Overview

This flowmeter is able to measure gas flow at low pressure, has multi-signal output and hyposensitivity flow disturbance technology. It combines the functions of gathering flow, temperature and pressure testing, and can carry out the temperature, pressure and compression factor compensation automatically. This is widely used in the measurement of natural gas, coal gasification, liquid gas, light hydrocarbon gas etc. The microprocessor has high reliability and operational precision. This leads to superior performance of flow monitoring in an inline gas pipe measurement.

Precession Vortex Flowmeter  – Features

  • Accuracy: 1.0~1.5%
  • Repeatability: Less than 1/3 of basic error absolute value
  • Working Power: 24VDC+3.6V battery power, can remove the battery
  • Output Signal: 4-20mA, pulse, RS485, alarm
  • Applicable Medium: All gases (except steam)
  • Integrates flow probe, microprocessor, pressure and temperature sensor
  • 16-bit computer chip, high integration, small volume, good performance, strong machine function
  • New signal processing amplifier & unique filtration technology
  • Dual-detection tech, improves detection signal strength, suppresses vibration
  • LCD display – temp, pressure, instantaneous flow & accumulative flow

Description

Precession Vortex Flowmeter | LUGB

Table 1: Precession Vortex Flow Meter Main Technical Parameters

Caliber

(mm)

20 25 32 50 80 100 150 200
Flow Range

(m3/h)

1.2~15 2.5~30 4.5~60 10~150 28~400 50~800 150~2250 360~3600
Accuracy   1.0~1.5%
Repeatability   Less than 1/3 of basic error absolute value
Working Pressure

(MPa)

  1.6Mpa, 2.5Mpa, 4.0Mpa, 6.3Mpa

Special pressure, please double-check

Application Condition   Environment temperature: -30℃~+65℃

Relative humidity: 5%~95%

Medium temperature: -20℃~+80℃

Atmospheric pressure: 86KPa~106KPa

Working Power   24VDC+3.6V battery power, can remove the battery
 Output Signal   4-20mA, pulse, RS485, alarm
 Applicable Medium   All gases (except steam)
Explosion-proof Mark   Ex ia II C T6 Ga

Table 2: Precession Vortex Flow Meter Size

Caliber

(mm)

 Length

(mm)

PN1.6~4.0MPa
 H  Dφ  Kφ  N  L  dφ  H  Kφ  N L  H N L
25 200  305  115  85  4  14  65
32 200  320  140  100  4  18  76
50 230  330  165  125  4  18  99
80 330  360  200  160  8  18  132
      PN1.6MPa       ※PN2.5~4.0MPa
100 410  376  220  180  8  18  156  390  235  190  8 22 156
150 570  430  285  240  8  22  211  450 300 250 8 26  211
      PN1.6MPa       PN2.5MPa       ※PN4.0MPa
200 700  470  340  295  12  22  266  490  360  310  12  26  274  510  375  320  12  30  284

Table 3: Precession Vortex Flow Meter Flow Range

DN(mm) Type Flow Range
(m³/h)
Working Pressure (MPa) Accuracy Level Repeatability
20 1.2~15 1.6

2.5

4.0

6.3

1.0

1.5

Less than 1/3 of basic error absolute value
25 2.5~30
32 4.5~60
50 B 10~150
80 B 28~400
100 B 50~800
150 B 150~2250
200 360~3600

Table 4: Precession Vortex Flow Meter Model Selection

LUGB XXX X X X X X X X X X
Caliber
(mm)
DN25-DN200 Reference Code,
please check caliber code table 1
Function With temperature & pressure compensation Y
Without temperature & pressure compensation N
Nominal
Pressure
1.6Mpa 1
2.5Mpa 2
4.0Mpa 3
6.3Mpa 4
Others 5
Connection Flange 1
Thread 2
WAFER 3
Others 4
Output Signal 4-20mA,pulse (two-wire system) 1
4-20mA,pulse (three-wire system) 2
RS485 communication 3
4-20mA, pulse,HART 4
Others 5
Alarm Low and high limit Alarm 6
Without 7
Accuracy Level 1.0 1
1.5 2
Cable Entry M20X1.5 M
1/2” NPT N
Structure
Type
Compact/Integral 1
Remote 2
Power
Supply
3.6V Lithium Battery, DC24V A
DC24V D
3.6V Lithium Battery E
Ex-proof With Ex-proof 0
Without Ex-proof 1
Shell Material Stainless Steel S
Aluminium Alloy L
Process
Connection
DIN PN16 1
DIN PN25 2
DIN PN40 3
ANSI 150# 4
ANSI 300# A
ANSI 600# B
JIS 10K C
JIS 20K D
JIS 40K E
Others F

 